SMM153  
I2C PROGRAMMING INFORMATION (CONTINUED)  
CONFIGURATION REGISTERS  
COMMAND AND STATUS REGISTERS  
The majority of the configuration registers are grouped  
with the general-purpose memory. Writing and reading  
the configuration registers is shown in Figures 7, 8 and  
9.  
Writes and reads of the command and status registers  
are shown in Figures 13 and 14.  
GRAPHICAL USER INTERFACE (GUI)  
Device configuration utilizing the Windows based  
SMM153 graphical user interface (GUI) is strongly  
recommended. The software is available from the  
Summit website (www.summitmicro.com). Using the  
GUI in conjunction with this datasheet simplifies the  
process of device prototyping and the interaction of  
the various functional blocks. A programming Dongle  
(SMX3200) is available from Summit to communicate  
with the SMM153. The Dongle connects directly to the  
parallel port of a PC and programs the device through  
a cable using the I2C bus protocol. See Figure 5 and  
the SMX3202 Data Sheet (www.summitmicro.com)..  
Note: Configuration writes or reads of registers 00 to  
03HEX must not be performed while the SMM153 is  
margining.  
GENERAL-PURPOSE MEMORY  
The 256-byte general-purpose memory is located at  
any slave address. The bus address bits are hard  
wired by the address pins A2, A1 and A0. They can be  
tied low, high or left floating, (Hi-Z). Memory writes and  
reads are shown in Figures 10, 11 and 12.  
Slave Address Bus Address Register Type  
Configuration Registers are located in  
00 HEX thru 05HEX and 30 HEX thru 3EHEX  
10XX  
A2 A1 A0  
General-Purpose Memory is located in  
40 HEX thru FF HEX  
Table 1 - Address bytes used by the SMB153.  
Slave Address programmed as 10XX (Z = Hi-Z state)  
Pins A[2:0]  
A2  
0
0
0
0
0
0
0
A1  
A0  
0
1
Z
0
1
Z
X
Slave Address  
1000  
Bus Address  
0
0
0
1
1
1
Z
000  
001  
010  
100  
101  
110  
011  
1000  
1000  
1000  
1000  
1000  
1000  
1
1
1
1
1
1
1
0
0
0
1
1
1
Z
0
1
Z
0
1
Z
X
1001  
1001  
1001  
1001  
1001  
1001  
1001  
000  
001  
010  
100  
101  
110  
011  
Z
Z
Z
Z
Z
Z
Z
0
0
0
1
1
1
Z
0
1
Z
0
1
Z
X
1010  
1010  
1010  
1010  
1010  
1010  
1010  
000  
001  
010  
100  
101  
110  
011  
Table 2 – Example device addresses allowed by the SMM153.  