SMH4042A
DCOPERATINGCHARACTERISTICS
(Over Recommended Operating Conditions; Voltages are relative to GND)
Symbol
Parameter
Supply voltage
Conditions (2)
Min.
Typ.
Max. Units
V
CC
(1)
1
V
I
Operating
Writing
500
3
µA
mA
V
CC1
Power Supply Current
I
CC2
V 5 A
CC
4.250
4.500
2.57
2.72
2.87
3.00
4.375
4.625
2.65
2.80
2.95
3.10
4.500
4.750
2.72
2.87
3.00
3.17
V 5 B
CC
V
HST_3V_MON G
HST_3V_MON H
HST_3V_MON K
HST_3V_MON L
CARD_5V_MON M
CARD_5V_MON N
V
V
V
V
V
(2) Threshold Levels
TRIP
V 5 + 50mV
CC
V
V 5 – 50mV
CC
V
HST_3V_MON +
50mV
CARD_3V_MON M
CARD_3V_MON N
V
V
HST_3V_MON –
50mV
V
Trip Point Hysteresis
7
mV
µA
µA
V
TRHYST
I
LI
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
LOCAL_PCI_RST# Low
RESET High
2
I
LO
10
0.8
V
IL
–0.1
2
V
IH
V
CC
+ 1V
V
V
OL
V
= 5.0V, I = 2.1mA
OL
0.4
V
CC
V
OH
V
I
= 5.0V, I = –400µA
OH
2.4
V
CC
V
OLRS
= 3.2mA
= –800µA
= 5µA
0.4
V
OL
V
OHRS
I
OH
V – 0.75V
CC
V
V
OHVG3
I
OH
12
13
13
14
15
15
V
VGATE3 High
V
OHVG5
I
OH
= 5µA
V
VGATE5 High
Reference Output Voltage No Load
V
0.95
40
1.00
50
1.05
60
V
REF
V
Circuit Breaker Trip Voltage (3)
mV
CB
2037 Elect Table 2.0
Notes:
(1) The SMH4042A will drive the Reset outputs and voltage control signals throughout the operating range of 1V to 5.5V. The balance
of the logic will not be guaranteed operational unless VCC is greater than 2.7V.
(2) A, B,G, H, K. L, M, & N refer to the Part Number Suffix.
(3) For TA = –10ºC to 85ºC.
SUMMIT MICROELECTRONICS, Inc.
2070 9.1 5/27/03
5