VN5010AK-E
Electrical specifications
Table 10. Current sense (8V<V <16V)
CC
Symbol
Parameter
Test conditions
Min. Typ. Max. Unit
IOUT= 0.25A;
VSENSE=0.5V;VCSD=0V;
K0
IOUT SENSE
/I
2770 5490 8220
Tj= -40°C...150°C
IOUT= 6A; VSENSE=0.5V; VCSD=0V;
Tj= -40°C...150°C
3610 4580 5630
3930 4580 5230
K1
IOUT/ISENSE
IOUT= 6A; VSENSE=0.5V; VCSD=0V;
Tj= 25°C...150°C
IOUT= 6A; VSENSE= 0.5V;
VCSD= 0V;
Current sense ratio
drift
(1)
dK1/K1
-8
+8
%
%
%
TJ= -40 °C to 150 °C
IOUT= 10A; VSENSE=4V; VCSD=0V;
Tj=-40°C...150°C
4000 4570 5220
4180 4570 4960
K2
IOUT/ISENSE
IOUT= 10A; VSENSE=4V; VCSD=0V;
Tj=25°C...150°C
IOUT= 10A; VSENSE= 4V;
VCSD=0V;
Current sense ratio
drift
(1)
dK2/K2
-5
+5
TJ= -40 °C to 150 °C
IOUT= 25A; VSENSE=4V; VCSD=0V;
Tj= -40°C...150°C
4480 4660 4980
4500 4660 4820
K3
IOUT/ISENSE
IOUT= 25A; VSENSE=4V; VCSD=0V;
Tj= 25°C...150°C
IOUT= 25A; VSENSE= 4V;
VCSD=0V;
Current sense ratio
drift
(1)
dK3/K3
-3
+3
TJ= -40 °C to 150 °C
IOUT= 0A; VSENSE=0V;
VCSD= 5V; VIN=0V; Tj= -40°C...150°C
VCSD= 0V; VIN=5V; Tj= -40°C...150°C
0
0
1
2
µA
µA
Analog sense
leakage current
ISENSE0
IOUT= 2A; VSENSE=0V;
VCSD=5V; VIN=5V; Tj= -40°C...150°C
0
1
µA
Openload On state
current detection
threshold
IOL
VIN = 5V, ISENSE= 5 µA
IOUT=15A; VCSD=0V;
10
45
mA
Max analog sense
output voltage
VSENSE
5
V
V
Analog sense output
voltage in
overtemperature
condition
VSENSEH
VCC= 13V; RSENSE= 3.9KΩ
9
8
Analog sense output
current in
overtemperature
condition
ISENSEH
VCC= 13V; VSENSE= 5V
mA