Electrical characteristics
STNRGPF01
5
Electrical characteristics
5.1
Parameter conditions
Unless otherwise specified, all voltages are referred to V . V
and V must be
DD
SS
DDA
connected to the same voltage value. V and V
must be connected together with the
SS
SSA
shortest wire loop.
5.1.1
5.1.2
Minimum and maximum values
Unless otherwise specified, the minimum and maximum values are guaranteed in the worst
conditions of ambient temperature, supply voltage and frequencies by tests in production on
100% of the devices with the ambient temperature at T = 25 °C and T = T max. (given by
A
A
A
the selected temperature range).
Data based on characterization results, design simulation and/or technology characteristics
are indicated according to each table specific notes and are not tested in production.
Typical values
Unless otherwise specified, typical data are based on T = 25 °C, V and V = 3.3 V.
DDA
A
DD
They are given only as design guidelines and are not tested. For the measurement section
the accuracy is determined by characterization of a batch of samples from a standard
diffusion lot over the full temperature range.
5.1.3
5.1.4
Typical curves
Unless otherwise specified, all typical curves are given as design guidelines only and are
not tested.
Typical current consumption
For typical current consumption measurements, V and V
are connected as shown in
DDA
DD
Figure 14.
Figure 14. Supply current measurement conditions
22/40
DocID030377 Rev 2