SM15TY
Table 2.
Characteristics
Electrical characteristics, typical values unless otherwise stated (T
RD
= 25 °C)
RD
amb
VCL @IPP
VCL @IPP
8/20 µs
(1)
IRM max@VRM
VBR @IR
10/1000
µs
8/20 αT (2)
10/1000 µs
µs
Order code
25 °C 85 °C
min typ max
V
max
max
max
10-4/
°C
µA
V
mA V(3) A(4)
Ω
V(3) A(4)
Ω
SM15T6V8AY/CAY 500 2000 5.8 6.45 6.8 7.14 10 10.5 143 0.023 13.4 746 0.008
SM15T7V5AY/CAY 250 1000 6.4 7.13 7.5 7.88 10 11.3 132 0.026 14.5 690 0.01
5.7
6.1
7.3
7.8
8.4
8.8
9.2
9.4
9.6
9.7
9.8
9.9
10
SM15T10AY/CAY
SM15T12AY/CAY
SM15T15AY/CAY
SM15T18AY/CAY
SM15T22AY/CAY
SM15T24AY/CAY
SM15T27AY/CAY
SM15T30AY/CAY
SM15T33AY/CAY
SM15T36AY/CAY
SM15T39AY/CAY
SM15T47AY/CAY
SM15T56AY/CAY
SM15T68AY/CAY
SM15T75AY/CAY
SM15T82AY/CAY
1. Pulse test: tp < 50 ms
10
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
50 8.55 9.5 10 10.5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
14.5 103 0.039 18.6 538 0.015
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10.2 11.4 12 12.6
12.8 14.3 15 15.8
15.3 17.1 18 18.9
18.8 20.9 22 23.1
20.5 22.8 24 25.2
23.1 25.7 27 28.4
25.6 28.5 30 31.5
28.2 31.4 33 34.7
30.8 34.2 36 37.8
33.3 37.1 39 41.0
40.2 44.7 47 49.4
48 53.3 56 58.9
58.1 64.6 68 71.4
64.1 71.3 75 78.8
70 77.8 82 86.0
16.7 90
21.2 71
0.046 21.7 461 0.02
0.076 27.2 368 0.031
25.2 59.5 0.106 32.5 308 0.044
30.6 49
0.153 39.3 254 0.064
0.178 42.8 234 0.075
0.228 48.3 207 0.096
0.278 53.5 187 0.12
33.2 45
37.5 40
41.5 36
45.7 33
0.333
59 169 0.14
49.9 30
0.403 64.3 156 0.17
0.461 69.7 143 0.2
53.9 28
64.5 23.2 0.653
84 119 0.291 10.1
77.4 20
92 16.3
103 14.6
113 13.9
0.925 100 100 0.411 10.3
1.26
1.66
1.94
121 83
0.6
10.4
10.5
10.5
134 75 0.74
146 69 0.87
2. To calculate maximum clamping voltage at other surge level, use the following formula: VCLmax = VCL - RD x (IPP - IPPappli
where IPPappli is the surge current in the application
)
3. To calculate VBR or VCL versus junction temperature, use the following formulas:
VBR @ TJ = VBR @ 25 °C x (1 + αT x (TJ - 25))
V
CL @ TJ = VCL @ 25 °C x (1 + αT x (TJ - 25))
4. Surge capability given for both directions for unidirectional and bidirectional types.
Doc ID 17865 Rev 3
3/12