M24C16, M24C08, M24C04, M24C02, M24C01
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
Table 6. Operating Conditions (M24Cxx-W)
Symbol
V
CC
T
A
Ambient Operating Temperature (Device Grade 3)
–40
125
°C
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Parameter
Min.
2.5
–40
Max.
5.5
85
Unit
V
°C
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 7. Operating Conditions (M24Cxx-R)
Symbol
V
CC
T
A
Supply Voltage
Ambient Operating Temperature
Parameter
Min.
1.8
–40
Max.
5.5
85
Unit
V
°C
Table 8. DC Characteristics (M24Cxx-W, Device Grade 6)
Symbol
I
LI
I
LO
I
CC
Parameter
Input Leakage Current
(SCL, SDA, E0, E1,and E2)
Output Leakage Current
Supply Current
V
CC
=2.5V, f
c
=400kHz (rise/fall time < 30ns)
V
IN
= V
SS
or V
CC
, V
CC
= 5 V
Stand-by Supply Current
V
IN
= V
SS
or V
CC
, V
CC
= 2.5 V
Input Low Voltage
Input High Voltage
Output Low Voltage
I
OL
= 2.1 mA, V
CC
= 2.5 V
–0.45
0.7V
CC
0.5
0.3V
CC
V
CC
+1
0.4
µA
V
V
V
1
1
mA
µA
Test Condition
(in addition to those in
V
IN
= V
SS
or V
CC
V
OUT
= V
SS
or V
CC,
SDA in Hi-Z
V
CC
=5V, f
c
=400kHz (rise/fall time < 30ns)
Min.
Max.
±2
±2
2
Unit
µA
µA
mA
I
CC1
V
IL
V
IH
V
OL
Note: 1. The voltage source driving only E0, E1 and E2 inputs must provide an impedance of less than 1kOhm.
13/25