M24C16, M24C08, M24C04, M24C02, M24C01
Table 9. DC Characteristics (M24Cxx-W, Device Grade 3)
Test Condition
(in addition to those in Table 6.)
Symbol
Parameter
Unit
Min.
Max.
Input Leakage Current
(SCL, SDA, E0, E1,and E2)
ILI
V
IN = VSS or VCC
± 2
µA
ILO
Output Leakage Current
Supply Current
VOUT = VSS or VCC, SDA in Hi-Z
± 2
3
µA
VCC=5V, f =400kHz (rise/fall time < 30ns)
mA
C
ICC
V
CC =2.5V, f =400kHz
C
3
mA
(rise/fall time < 30ns)
VIN = VSS or VCC , VCC = 5 V
VIN = VSS or VCC , VCC = 2.5 V
5
2
µA
µA
V
ICC1
Stand-by Supply Current
(1)
VIL
VIH
VOL
–0.45
0.3VCC
Input Low Voltage
(1)
0.7VCC
VCC+1
0.4
V
V
Input High Voltage
Output Low Voltage
IOL = 2.1 mA, VCC = 2.5 V
Note: 1. The voltage source driving only E0, E1 and E2 inputs must provide an impedance of less than 1kOhm.
Table 10. DC Characteristics (M24Cxx-R)
Test Condition
Symbol
Parameter
Min.
Max.
Unit
(in addition to those in Table 7.)
Input Leakage Current
(SCL, SDA, E0, E1,and E2)
ILI
V
IN = VSS or VCC
± 2
µA
ILO
ICC
Output Leakage Current
Supply Current
V
OUT = VSS or VCC, SDA in Hi-Z
± 2
0.8
µA
mA
µA
V
V
CC =1.8V, f =400kHz (rise/fall time < 30ns)
c
ICC1
Stand-by Supply Current
V
IN = VSS or VCC , VCC = 1.8 V
2.5 V ≤VCC
0.3
–0.45
–0.45
0.3 VCC
0.25 VCC
VCC+1
0.2
(1)
VIL
Input Low Voltage
1.8 V ≤VCC < 2.5 V
V
(1)
VIH
0.7VCC
V
Input High Voltage
VOL
Output Low Voltage
IOL = 0.7 mA, VCC = 1.8 V
V
Note: 1. The voltage source driving only E0, E1 and E2 inputs must provide an impedance of less than 1kOhm.
Table 11. AC Measurement Conditions
Symbol
Parameter
Min.
Max.
Unit
C
Load Capacitance
100
pF
ns
V
L
Input Rise and Fall Times
Input Levels
50
0.2V to 0.8V
CC
CC
CC
0.3V to 0.7V
Input and Output Timing Reference Levels
V
CC
14/25