欢迎访问ic37.com |
会员登录 免费注册
发布采购

CYW320OXC-3T 参数 Datasheet PDF下载

CYW320OXC-3T图片预览
型号: CYW320OXC-3T
PDF下载: 下载PDF文件 查看货源
内容描述: 200 MHz的扩频时钟合成器/驱动器,带有差分CPU输出 [200 MHz Spread Spectrum Clock Synthesizer/Driver with Differential CPU Outputs]
分类和应用: 晶体驱动器外围集成电路光电二极管时钟
文件页数/大小: 16 页 / 251 K
品牌: SPECTRALINEAR [ SPECTRALINEAR INC ]
 浏览型号CYW320OXC-3T的Datasheet PDF文件第1页浏览型号CYW320OXC-3T的Datasheet PDF文件第2页浏览型号CYW320OXC-3T的Datasheet PDF文件第3页浏览型号CYW320OXC-3T的Datasheet PDF文件第5页浏览型号CYW320OXC-3T的Datasheet PDF文件第6页浏览型号CYW320OXC-3T的Datasheet PDF文件第7页浏览型号CYW320OXC-3T的Datasheet PDF文件第8页浏览型号CYW320OXC-3T的Datasheet PDF文件第9页  
W320-03  
ability to stop after any complete byte has been transferred.  
Indexed bytes are not allowed.  
Serial Data Interface (SMBus)  
To enhance the flexibility and function of the clock synthesizer,  
a two signal SMBus interface is provided according to the  
SMBus specification. Through the Serial Data Interface (SDI),  
various device functions such as individual clock output  
buffers, etc can be individually enabled or disabled. W320-03  
support both block read and block write operations.  
A block write begins with a slave address and a WRITE  
condition. The R/W bit is used by the SMBus controller as a  
data direction bit. A zero indicates a WRITE condition to the  
clock device. The slave receiver address is 11010010 (D2h).  
A command code of 0000 0000 (00h) and the byte count bytes  
are required for any transfer. After the command code, the  
core logic issues a byte count which describes number of  
additional bytes required for the transfer, not including the  
command code and byte count bytes. For example, if the host  
has 20 data bytes to send, the first byte would be the number  
20 (14h), followed by the 20 bytes of data. The byte count byte  
is required to be a minimum of one byte and a maximum of 32  
bytes It may not be 0. Figure 1 shows an example of a block  
write.  
The registers associated with the SDI initialize to their default  
setting upon power-up, and therefore use of this interface is  
optional. Clock device register changes are normally made  
upon system initialization, if any are required. The interface  
can also be used during system operation for power  
management functions.  
Data Protocol  
The clock driver serial protocol accepts only block writes from  
the controller. The bytes must be accessed in sequential order  
from lowest to highest byte, (most significant bit first) with the  
A transfer is considered valid after the acknowledge bit corre-  
sponding to the byte count is read by the controller.  
Start Slave Address R/W  
bit 1 1 0 1 0 0 1 0 0/1  
A
1
Command  
Code  
0 0 0 0 0 0 0 0  
A ByteCount= A Data Byte 0  
N
A
1
. . .  
Data Byte N-1 A Stop  
bit  
1 bit  
7 bits  
1
8 bits  
1
8 bits  
1
8 bits  
8 bits  
1
1 bit  
From Master to Slave  
From Slave to Master  
Figure 1. An Example of a Block Write  
Data Byte Configuration Map  
Data Byte 0: Control Register (0 = Enable, 1 = Disable)  
Power On  
Default  
Bit  
Affected Pin#  
Name  
Description  
Spread Spectrum Enable  
0 = Spread Off, 1 = Spread On  
Type  
Bit 7  
5, 6, 7, 10, 11, PCI [0:6]  
12, 13, 16, 17, CPU[2:0]  
R/W  
0
18, 33, 35  
3V66[1:0]  
Bit 6  
Bit 5  
TBD  
TBD  
R
0
0
35  
3V66_1/VCH  
VCH Select 66 MHz/48 MHz  
0 = 66 MHz, 1 = 48 MHz  
R/W  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
44, 45, 48, 49, CPU [2:0]  
51, 52 CPU# [2:0]  
CPU_STOP#  
Reflects the current value of the external CPU_STOP# pin  
R
N/A  
N/A  
N/A  
N/A  
N/A  
10, 11, 12, 13, PCI [6:0]  
16, 17, 18  
PCI_STOP#  
(Does not affect PCI_F [2:0] pins)  
R/W  
R
S2  
Reflects the value of the S2 pin sampled on Power-up  
S1  
Reflects the value of the S1 pin sampled on Power-up  
R
S0  
Reflects the value of the S1 pin sampled on Power-up  
R
Rev 1.0,November 25, 2006  
Page 4 of 16