MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90
• Write/Erase/Program Operations
Value
Symbol
Parameter
-55
-70
-90
Unit
JEDEC Standard
Min Typ Max Min Typ Max Min Typ Max
Write Cycle Time
tAVAV
tAVWL
tWLAX
tDVWH
tWHDX
—
tWC
tAS
55
0
70
0
90
0
ns
ns
ns
ns
ns
ns
ns
Address Setup Time
Address Hold Time
Data Setup Time
tAH
40
25
0
45
30
0
45
45
0
tDS
Data Hold Time
tDH
tOES
Output Enable Setup Time
0
0
0
Read
0
0
0
Output Enable
—
tOEH
Toggle and Data
Polling
Hold Time
10
10
10
ns
Read Recover Time Before Write tGHWL
tGHWL
tGHEL
tCS
0
0
0
0
0
0
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
µs
s
Read Recover Time Before Write
CE Setup Time
tGHEL
tELWL
tWLEL
tWHEH
tEHWH
tWLWH
tELEH
tWHWL
tEHEL
0
0
0
WE Setup Time
tWS
0
0
0
CE Hold Time
tCH
0
0
0
WE Hold Time
tWH
0
0
0
Write Pulse Width
CE Pulse Width
tWP
30
30
20
20
35
35
20
20
45
45
20
20
tCP
Write Pulse Width High
CE Pulse Width High
tWPH
tCPH
Byte
8
16
1
8
16
1
8
16
1
Programming
Operation
tWHWH1
tWHWH1
tWHWH2
Word
Sector Erase Operation *1
tWHWH2
8
8
8
s
VCC Setup Time
—
—
—
—
—
—
—
tVCS
tVIDR
tVLHT
tWPP
tOESP
tCSP
tRB
50
500
4
50
500
4
50
500
4
µs
ns
µs
µs
µs
µs
ns
RiseTime to VID
Voltage Transition Time *2
Write Pulse Width *2
100
4
100
4
100
4
OE Setup Time to WE Active *2
CE Setup Time to WE Active *2
Recover Time from RY/BY
4
4
4
0
0
0
(Continued)
26