MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90
■ DC CHARACTERISTICS
Value
Parameter
Symbol
Conditions
Unit
Min
–1.0
–1.0
Max
+1.0
+1.0
Input Leakage Current
Output Leakage Current
ILI
VIN = VSS to VCC, VCC = VCC Max
VOUT = VSS to VCC, VCC = VCC Max
µA
µA
ILO
A9, OE, RESET Inputs Leakage
Current
VCC = VCC Max,
A9, OE, RESET = 12.5 V
ILIT
—
—
50
µA
Byte
CE = VIL, OE = VIH
Word
38
45
50
VCC Active Current *1
VCC Active Current *2
ICC1
ICC2
mA
CE = VIL, OE = VIH
—
—
mA
mA
VCC = VCC Max, CE = VIH,
RESET = VIH
1
5
1
5
VCC Current (Standby)
ICC3
ICC4
VCC = VCC Max, CE = VCC ± 0.3 V,
RESET = VCC ± 0.3 V
—
—
—
µA
mA
µA
VCC = VCC Max,
RESET = VIL
VCC Current (Standby, Reset)
VCC = VCC Max,
RESET = VSS ± 0.3 V
Input Low Level
Input High Level
VIL
VIH
—
—
–0.5
2.0
0.8
V
V
VCC + 0.5
Voltage for Autoselect and
Sector Protection
VID
—
11.5
12.5
V
(A9, OE, RESET) *3, *4
Output Low Voltage Level
Output High Voltage Level
Low VCC Lock-Out Voltage
VOL
VOH1
VOH2
VLKO
IOL = 5.8 mA, VCC = VCC Min
IOH = –2.5 mA, VCC = VCC Min
IOH = –100 µA
—
2.4
0.45
—
V
V
V
V
VCC – 0.4
3.2
—
—
4.2
*1 : The ICC current listed includes both the DC operating current and the frequency dependent component (at
6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH.
*2 : ICC active while Embedded Algorithm (program or erase) is in progress.
*3 : Applicable to sector protection function.
*4 : (VID – VCC) do not exceed 9 V.
24