MBM29F040C-55/-70/-90
■ DC CHARACTERISTICS
Parameter
Symbol
Parameter Description
Test Conditions
Min.
Max.
Unit
ILI
Input Leakage Current
VIN = VSS to VCC, VCC = VCC Max
VOUT = VSS to VCC, VCC = VCC Max
VCC = VCC Max., A9, OE = 12.0 V
CE = VIL, OE = VIH
—
—
±1.0
±1.0
50
µA
µA
µA
mA
mA
mA
µA
V
ILO
Output Leakage Current
A9, OE Input Leakage Current
VCC Active Current (Note 1)
VCC Active Current (Note 2)
ILIT
—
ICC1
ICC2
—
30
CE = VIL, OE = VIH
—
45
VCC = VCC Max., CE = VIH
VCC = VCC Max., CE = VCC±0.3 V
—
—
1
ICC3
VCC Current (Standby)
—
5
VIL
VIH
Input Low Level
Input High Level
–0.5
2.0
0.8
—
VCC+0.3
V
Voltage for Autoselect and Sector
Protection (A9, OE) (Note 3, 4)
VID
VCC = 5.0 V
11.5
12.5
V
VOL
Output Low Voltage Level
Output High Voltage Level
Low VCC Lock-Out Voltage
IOL = 12.0 mA, VCC = VCC Min
IOH = –2.5 mA, VCC = VCC Min
IOH = –100 µA
—
2.4
0.45
—
V
V
V
V
VOH1
VOH2
VLKO
VCC–0.4
3.2
—
—
4.2
Notes:1. The ICC current listed includes both the DC operating current and the frequency dependent component
(at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH.
2. ICC active while Embedded Algorithm (program or erase) is in progress.
3. Applicable to sector protection function.
4. (VID – VCC) do not exceed 9 V.
21