D A T A S H E E T
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +125°C
20 ns
20 ns
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55°C to +125°C
+0.8 V
Voltage with Respect to Ground
–0.5 V
–2.0 V
V
(Note 1). . . . . . . . . . . . . . . . . . . .–2.0 V to +7.0 V
CC
A9 (Note 2). . . . . . . . . . . . . . . . . . . .–2.0 V to +13.0 V
All other pins (Note 1) . . . . . . . . . . . .–2.0 V to +7.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
20 ns
Figure 5. Maximum Negative
Overshoot Waveform
1. Minimum DC voltage on input or I/O pin is –0.5 V. During
voltage transitions, inputs may overshoot VSS to –2.0 V
for periods of up to 20 ns. See Figure 5. Maximum DC
voltage on input and I/O pins is VCC + 0.5 V. During volt-
age transitions, input and I/O pins may overshoot to VCC
+ 2.0 V for periods up to 20 ns. See Figure 6.
20 ns
2. Minimum DC input voltage on A9 pin is –0.5V. During
voltage transitions, A9 pins may overshoot VSS to –2.0 V
VCC
+2.0 V
VCC
for periods of up to 20 ns. See Figure 5. Maximum DC in-
put voltage on A9 is +12.5 V which may overshoot to 14.0
V for periods up to 20 ns.
+0.5 V
2.0 V
3. No more than one output shorted at a time. Duration of
the short circuit should not be greater than one second.
20 ns
20 ns
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the op-
erational sections of this specification is not implied. Expo-
sure of the device to absolute maximum rating conditions for
extended periods may affect device reliability.
Figure 6. Maximum Positive
Overshoot Waveform
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T ) . . . . . . . . . . . 0°C to +70°C
A
Industrial (I) Devices
Ambient Temperature (T ) . . . . . . . . . –40°C to +85°C
A
Extended (E) Devices
Ambient Temperature (T ) . . . . . . . . –55°C to +125°C
A
V
V
V
Supply Voltages
CC
CC
CC
for 5% devices . . . . . . . . . . .+4.75 V to +5.25 V
for 10% devices . . . . . . . . . .+4.50 V to +5.50 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
October 31, 2006 Am29F010B_00_C7
Am29F010B
17