欢迎访问ic37.com |
会员登录 免费注册
发布采购

AM29BDS64HE9VKI 参数 Datasheet PDF下载

AM29BDS64HE9VKI图片预览
型号: AM29BDS64HE9VKI
PDF下载: 下载PDF文件 查看货源
内容描述: 128或64兆比特( 8 M或4米×16位) CMOS 1.8伏只同步读/写,突发模式闪存 [128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory]
分类和应用: 闪存
文件页数/大小: 89 页 / 1587 K
品牌: SPANSION [ SPANSION ]
 浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第45页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第46页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第47页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第48页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第50页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第51页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第52页浏览型号AM29BDS64HE9VKI的Datasheet PDF文件第53页  
D A T A S H E E T  
Table 21. Sector Protection Command Definitions  
Bus Cycles (Notes 1–6)  
First  
Second  
Third  
Addr  
Fourth  
Fifth  
Addr  
Sixth  
Data Addr Data  
Seventh  
Command Sequence  
(Notes)  
Addr Data Addr Data  
Data  
88  
Addr  
Data  
Addr Data  
Entry  
Exit  
3
4
555  
555  
AA  
AA  
2AA  
2AA  
55  
55  
555  
555  
90  
XX  
00  
68  
Protection Bit  
Program (8, 9)  
6
555  
AA  
2AA  
55  
555  
60  
SA+OW  
SA+OW  
48  
OW  
RD(0)  
Program (11)  
Verify (11)  
4
4
7
6
555  
555  
555  
555  
AA  
AA  
AA  
AA  
2AA  
2AA  
2AA  
2AA  
55  
55  
55  
55  
555  
555  
555  
555  
38  
C8  
28  
60  
XX[0–3]  
XX[0–3]  
XX0  
PD[0–3]  
PD[0–3]  
PD0  
Unlock (11)  
Program (8, 9)  
XX1  
PD1  
48  
XX2  
XX  
PD2  
XX3  
PD3  
SBA+WP  
68  
SBA+WP  
RD(0)  
All Erase  
SBA+  
WPE  
6
555  
AA  
2AA  
55  
555  
60  
WPE  
60  
40  
XX  
RD(0)  
(8, 10, 12)  
Status (13)  
Set  
4
3
4
4
4
4
555  
555  
555  
555  
555  
555  
AA  
AA  
AA  
AA  
AA  
AA  
2AA  
2AA  
2AA  
2AA  
2AA  
2AA  
55  
55  
55  
55  
55  
55  
BA+555  
555  
90  
78  
58  
48  
48  
58  
SBA+WP  
RD(0)  
Status (8)  
Write  
BA+555  
555  
SA  
SA  
SA  
SA  
RD(1)  
X1  
Erase  
555  
X0  
Status  
BA+555  
RD(0)  
Locking Bit Program  
(8, 9)  
6
6
555  
555  
AA  
AA  
2AA  
2AA  
55  
55  
555  
555  
60  
60  
PL  
SL  
68  
68  
PL  
SL  
48  
48  
PL  
SL  
RD(0)  
RD(0)  
Locking Bit Program  
(8, 9)  
Legend:  
X = Don’t care  
PWA = Password Address. Address bits A1 and A0 are used to select  
each 16-bit portion of the 64-bit entity.  
PA = Address of the memory location to be programmed. Addresses latch  
on the rising edge of the AVD# pulse or active edge of CLK which ever  
comes first.  
PL = Address (A7–A0) is (00001010)  
RD(0) = DQ0 protection indicator bit. If protected, DQ0 = 1.  
If unprotected, DQ0 = 0.  
SA = Address of the sector to be verified (in autoselect mode) or erased.  
Address bits Amax–A12 uniquely select any sector.  
RD(1) = DQ1 protection indicator bit. If protected, DQ1 = 1.  
If unprotected, DQ1 = 0.  
BA = Address of the bank (BDS128H: A22–A20; BDS640H: A21–A19) for  
which command is being written.  
SBA = Sector address block to be protected.  
SL = Address (A7–A0) is (00010010)  
SLA = Address of the sector to be locked. Set sector address (SA) and  
either A6 = 1 for unlocked or A6 = 0 for locked.  
WD= Write Data. See “Configuration Register” definition for specific write  
data  
OW = Address (A7–A0) is (00011010).  
PD3–PD0 = Password Data. PD3–PD0 present four 16 bit combinations  
that represent the 64-bit password.  
WP = Address (A7–A0) is (00000010)  
WPE = Address (A7–A0) is (01000010)  
Notes:  
1. See Table 1 for description of bus operations.  
9. The fourth cycle programs the addressed locking bit. The fifth and  
sixth cycles are used to validate whether the bit has been fully  
programmed. If DQ0 (in the sixth cycle) reads 0, the program  
command must be issued and verified again.  
2. All values are in hexadecimal.  
3. Shaded cells indicate read cycles. All others are write cycles.  
4. Data bits DQ15–DQ8 are don’t care in command sequences, except  
for RD, PD, WD, PWD, and PD3–PD0.  
10. The fourth cycle erases all PPBs. The fifth and sixth cycles are used  
to validate whether the bits have been fully erased. If DQ0 (in the  
sixth cycle) reads 1, the erase command must be issued and verified  
again.  
5. Unless otherwise noted, address bits Amax–A12 are don’t cares.  
6. Writing incorrect address and data values or writing them in the  
improper sequence may place the device in an unknown state. The  
system must write the reset command to return the device to  
reading array data.  
11. The entire four bus-cycle sequence must be entered for each portion  
of the password.  
12. Before issuing the erase command, all PPBs should be programmed  
in order to prevent over-erasure of PPBs.  
7. No unlock or command cycles required when bank is reading array  
data.  
13. In the fourth cycle, 01h indicates PPB set; 00h indicates PPB not  
set.  
8. Not supported in Synchronous Read Mode, command mode verify  
are always asynchronous read operations.  
May 10, 2006 27024B3  
Am29BDS128H/Am29BDS640H  
47