CXD1968AR
Transport Stream Interface (Serial Mode)
(0°C < Ta < 70°C, AVSS = 0V, DVSS = 0V, CVSS = 0V, 3.15V ≤ AVDD ≤ 3.45V, 3.15V ≤ DVDD ≤ 3.45V, 1.08V
≤ CVDD ≤ 1.32V)
Item
Symbol Condition
Min. Typ. Max. Unit
tTSLOCK,
Transport stream locked to valid TSSYNC,
TSVALID and TSERR
(1)
146
ns
ns
ns
tTSJIT(E),
(2)
(3)
1
Transport stream clock jitter (smoothing enabled)
tTSSU,
Transport stream TSDATA, TSSYNC, TSVALID
and TSERR setup time to TSCLK active edge
6
tTSPW(E),
Transport stream TSCLK pulse width
(smoothing enabled)
(4)
12.2
41
ns
MHz
ns
fTSCLK(E),
Transport stream TSCLK frequency
(smoothing enabled)
tTSHD,
Transport stream TSDATA, TSSYNC, TSVALID
and TSERR hold time from TSCLK active edge
(5)
3
Note) The items in the above table are applicable only if transport stream smoothing is enabled.
Use of the serial transport stream output interface with transport stream smoothing disabled is not
recommended.
(4)
TSCLK
(3)
(2)
TSDATA(7)/(0)
(5)
TSSYNC
TSVALID,
TSERR
Lock
Transport
Stream
Locked
(1)
Tranport Stream Interface (Serial Mode)
- 39 -