CXA3185/3186N
1
2
3
Measured value for untuned inputs.
Noise figure is the direct-reading value of NF meter in DSB.
Desired signal (fD) input level is –30 dBm. Undesired signal (fUD) is 100 kHz, 30 % AM.
The measurement value is undesired signal level, it measured with a spectrum analyzer at S/I=46 dBm.
Value when the PLL is not operating.
4
PLL Block
Item
CL and DA pins
Symbol
Measurement conditions
Min.
Typ.
Max.
Unit
“H” level input voltage VIH
“L” level input voltage VIL
“H” level input current IIH
“L” level input current IIL
CE pins
3
VCC
1.5
V
V
GND
VIH = VCC
0
–0.1
–2
µA
µA
VIL = GND
–1
“H” level input voltage VIHE
“L” level input voltage VILE
“H” level input current IIHE
“L” level input current IILE
CPO (charge pump)
3
VCC
1.5
V
V
GND
VIHE=VCC
100
–30
130
–45
µA
µA
VILE=GND
Output current
Leak current
LOCK
ICPO
±35
±50
±75
30
µA
nA
LeakCP
“H” output voltage
“L” output voltage
REFOSC
VLOCKH
VLOCKL
When locked
VCC–0.5
0
VCC
V
V
When unlocked
0.5
Oscillator
FXTOSC
3
12
MHz
frequency range
Input capacitance
Drive level
CXTOSC
VXTOSC
17.5
200
19
20.5
pF
400
mVp-p
BVL, BVH, BU (Band SW)
Output current
Saturation voltage
Leak current
IBS1
When ON
–25
200
3
mA
mV
µA
VSAT1
When ON Sink current = 20 mA
100
0.5
LeakBS1 When OFF
FMT (Band SW)
Output current
Saturation voltage
Leak current
IBS2
When ON
–7
150
0.1
mA
mV
µA
VSAT2
When ON Sink current = 5 mA
75
LeakBS2 When OFF
0.03
Bus timing
Data setup time
Data hold time
Enable waiting time
Enable setup time
Enable hold time
tSD
tHD
tWE
tSE
tHE
See Timing Chart on Page 15
300
600
300
300
600
ns
ns
ns
ns
ns
See Timing Chart on Page 15
See Timing Chart on Page 15
See Timing Chart on Page 15
See Timing Chart on Page 15
—7—