CXA3185/3186N
Electrical Characteristics
See the Electrical Characteristics Measurement Circuit.
Circuit Current
(VCC=5 V, Ta=25 °C)
Item
Symbol
Measurement conditions
VCC1 current, Band switch output
open during VHF operation
VCC1 current, Band switch output
open during UHF operation
VCC2 current
Min.
30
Typ.
41
Max.
55
Unit
mA
Circuit current A
AICCV
AICCU
31
7
42
11
56
15
mA
mA
Circuit current D
DICC
OSC/MIX/IF Amplifier Block
Item
Symbol
Measurement conditions
VHF operation fRF = 55 MHz
VHF operation fRF = 360 MHz
UHF operation fRF = 360 MHz
UHF operation fRF = 800 MHz
VHF operation fRF = 55 MHz
VHF operation fRF = 360 MHz
UHF operation fRF = 360 MHz
UHF operation fRF = 800 MHz
VHF operation
Min.
21
Typ.
24
Max.
27
Unit
dB
dB
dB
dB
dB
dB
dB
dB
1
Conversion gain
CG1
CG2
CG3
CG4
NF1
NF2
NF3
NF4
22
25
28
26
29
32
27
30
33
1
2
Noise figure
,
12
15
11
14
8.5
9.5
12.5
13.5
1 % cross
CM1
CM2
CM3
CM4
97
96
92
101
100
96
dBµ
dBµ
dBµ
1
3
modulation
,
fD = 55 MHz, fUD = ±12 MHz
VHF operation
fD = 360 MHz, fUD = ±12 MHz
UHF operation
fD = 360 MHz, fUD = ±12 MHz
UHF operation
88
+5
92
dBµ
dBm
kHz
fD = 800 MHz, fUD = ±12 MHz
50 Ω load saturation output
VHF operation fOSC = 100 MHz
∆f from 3 s to 3 min after switch ON
VHF operation fOSC = 405 MHz
∆f from 3 s to 3 min after switch ON
UHF operation fOSC = 405 MHz
∆f from 3 s to 3 min after switch ON
UHF operation fOSC = 845 MHz
∆f from 3 s to 3 min after switch ON
VHF operation fOSC = 100 MHz
∆f when VCC 5 V changes ±5 %
VHF operation fOSC = 405 MHz
∆f when VCC 5 V changes ±5 %
UHF operation fOSC = 405 MHz
∆f when VCC 5 V changes ±5 %
UHF operation fOSC = 845 MHz
∆f when VCC 5 V changes ±5 %
Maximum output power Pomax
+10
4
Switch ON drift
∆fsw1
∆fsw2
∆fsw3
±300
±400
±400
±500
±150
±250
±200
±250
kHz
kHz
kHz
kHz
kHz
kHz
kHz
∆fsw4
Supply voltage drift
∆fst1
4
∆fst2
∆fst3
∆fst4
—6—