Advanced I/O Controller with Motherboard GLUE Logic  
Datasheet  
Table 6.23 - Verify Command Result Phase Table  
SC/EOT VALUE TERMINATION RESULT  
MT  
EC  
SC = DTL  
EOT <= # Sectors Per Side  
SC = DTL  
EOT > # Sectors Per Side  
SC <= # Sectors Remaining AND  
EOT <= # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
SC = DTL  
EOT <= # Sectors Per Side  
SC = DTL  
EOT > # Sectors Per Side  
SC <= # Sectors Remaining AND  
EOT <= # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
Success Termination  
0
0
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
0
0
0
1
1
1
1
0
1
1
0
0
1
1
Unsuccessful Termination  
Result Phase Invalid  
Note:  
If MT is set to “1” and the SC value is greater than the number of remaining formatted sectors on Side 0,  
verifying will continue on Side 1 of the disk.  
6.17 Format A Track  
The Format command allows an entire track to be formatted. After a pulse from the nINDEX pin is  
detected, the FDC starts writing data on the disk including gaps, address marks, ID fields, and data fields  
per the IBM System 34 or 3740 format (MFM or FM respectively). The particular values that will be written  
to the gap and data field are controlled by the values programmed into N, SC, GPL, and D which are  
specified by the host during the command phase. The data field of the sector is filled with the data byte  
specified by D. The ID field for each sector is supplied by the host; that is, four data bytes per sector are  
needed by the FDC for C, H, R, and N (cylinder, head, sector number and sector size respectively).  
After formatting each sector, the host must send new values for C, H, R and N to the FDC for the next  
sector on the track. The R value (sector number) is the only value that must be changed by the host after  
each sector is formatted. This allows the disk to be formatted with nonsequential sector addresses  
(interleaving). This incrementing and formatting continues for the whole track until the FDC encounters a  
pulse on the nINDEX pin again and it terminates the command.  
Table 6.24 contains typical values for gap fields that are dependent upon the size of the sector and the  
number of sectors on each track. Actual values can vary due to drive electronics.  