Table 16 Description of Command Symbols  
SYMBOL  
NAME  
DESCRIPTION  
DS0, DS1 Disk Drive Select  
DS1  
0
0
DS0  
0
1
DRIVE  
Drive 0  
Drive 1  
DTL  
Special Sector  
Size  
By setting N to zero (00), DTL may be used to control the number of  
bytes transferred in disk read/write commands. The sector size (N =  
0) is set to 128. If the actual sector (on the diskette) is larger than  
DTL, the remainder of the actual sector is read but is not passed to  
the host during read commands; during write commands, the  
remainder of the actual sector is written with all zero bytes. The CRC  
check code is calculated with the actual sector. When N is not zero,  
DTL has no meaning and should be set to FF HEX.  
EC  
EFIFO  
EIS  
Enable Count  
Enable FIFO  
When this bit is "1" the "DTL" parameter of the Verify command  
becomes SC (number of sectors per track).  
This active low bit when a 0, enables the FIFO. A "1" disables the  
FIFO (default).  
Enable Implied  
Seek  
When set, a seek operation will be performed before executing any  
read or write command that requires the C parameter in the  
command phase. A "0" disables the implied seek.  
EOT  
GAP  
GPL  
End of Track  
The final sector number of the current track.  
Alters Gap 2 length when using Perpendicular Mode.  
Gap Length  
The Gap 3 size. (Gap 3 is the space between sectors excluding the  
VCO synchronization field).  
H/HDS  
HLT  
Head Address  
Head Load Time  
Selected head: 0 or 1 (disk side 0 or 1) as encoded in the sector ID  
field.  
The time interval that FDC waits after loading the head and before  
initializing a read or write operation. Refer to the Specify command  
for actual delays.  
HUT  
Head Unload  
Time  
The time interval from the end of the execution phase (of a read or  
write command) until the head is unloaded. Refer to the Specify  
command for actual delays.  
LOCK  
Lock defines whether EFIFO, FIFOTHR, and PRETRK parameters of  
the CONFIGURE COMMAND can be reset to their default values by  
a "software Reset". (A reset caused by writing to the appropriate bits  
of either the DSR or DOR)  
MFM  
MT  
MFM/FM Mode  
Selector  
A one selects the double density (MFM) mode. A zero selects single  
density (FM) mode.  
Multi-Track  
Selector  
When set, this flag selects the multi-track operating mode. In this  
mode, the FDC treats a complete cylinder under head 0 and 1 as a  
single track. The FDC operates as this expanded track started at the  
first sector under head 0 and ended at the last sector under head 1.  
With this flag set, a multitrack read or write operation will  
automatically continue to the first sector under head 1 when the FDC  
finishes operating on the last sector under head 0.  
SMSC DS – LPC47S45x  
Page 43 of 259  
Rev. 07/09/2001  
DATASHEET  