Table 23 - Verify Command Result Phase  
SC/EOT VALUE TERMINATION RESULT  
MT  
EC  
0
0
SC = DTL  
Success Termination  
Result Phase Valid  
EOT # Sectors Per Side  
SC = DTL  
0
0
0
1
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
EOT > # Sectors Per Side  
SC # Sectors Remaining AND  
EOT # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
SC = DTL  
0
1
1
1
1
1
0
0
1
1
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
EOT # Sectors Per Side  
SC = DTL  
EOT > # Sectors Per Side  
SC # Sectors Remaining AND  
EOT # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
Unsuccessful Termination  
Result Phase Invalid  
Note:  
If MT is set to "1" and the SC value is greater than the number of remaining formatted sectors on Side 0,  
verifying will continue on Side 1 of the disk.  
Format A Track  
The Format command allows an entire track to be formatted. After a pulse from the nINDEX pin is detected, the FDC  
starts writing data on the disk including gaps, address marks, ID fields, and data fields per the IBM System 34 or 3740  
format (MFM or FM respectively). The particular values that will be written to the gap and data field are controlled by the  
values programmed into N, SC, GPL, and D which are specified by the host during the command phase. The data field  
of the sector is filled with the data byte specified by D. The ID field for each sector is supplied by the host; that is, four  
data bytes per sector are needed by the FDC for C, H, R, and N (cylinder, head, sector number and sector size  
respectively).  
After formatting each sector, the host must send new values for C, H, R and N to the FDC for the next sector on the  
track. The R value (sector number) is the only value that must be changed by the host after each sector is formatted.  
This allows the disk to be formatted with nonsequential sector addresses (interleaving). This incrementing and  
formatting continues for the whole track until the FDC encounters a pulse on the nINDEX pin again and it terminates the  
command.  
Table 24 contains typical values for gap fields which are dependent upon the size of the sector and the number of  
sectors on each track. Actual values can vary due to drive electronics.  
SMSC LPC47B27x  
- 48 -  
Rev. 08-10-04  
DATASHEET  