欢迎访问ic37.com |
会员登录 免费注册
发布采购

LAN9210 参数 Datasheet PDF下载

LAN9210图片预览
型号: LAN9210
PDF下载: 下载PDF文件 查看货源
内容描述: 外形小巧单芯片以太网控制器与HP Auto-MDIX的 [Small Form Factor Single- Chip Ethernet Controller with HP Auto-MDIX]
分类和应用: 控制器以太网
文件页数/大小: 458 页 / 4618 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号LAN9210的Datasheet PDF文件第53页浏览型号LAN9210的Datasheet PDF文件第54页浏览型号LAN9210的Datasheet PDF文件第55页浏览型号LAN9210的Datasheet PDF文件第56页浏览型号LAN9210的Datasheet PDF文件第58页浏览型号LAN9210的Datasheet PDF文件第59页浏览型号LAN9210的Datasheet PDF文件第60页浏览型号LAN9210的Datasheet PDF文件第61页  
High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface  
Datasheet  
CSR Write Auto  
CSR Write Direct  
Address  
CSR Write  
Increment /  
Decrement  
Idle  
Idle  
Idle  
Write  
Direct  
Data  
Write  
Command  
Register  
Write Data  
Register  
Register  
Range  
min wait period  
Write  
Command  
Register  
Read  
Command  
Register  
Write Data  
Register  
CSR_BUSY = 0  
CSR_BUSY = 1  
min wait period  
min wait period  
Read  
Read  
Command  
Register  
Command  
Register  
CSR_BUSY = 0  
CSR_BUSY = 1  
CSR_BUSY = 0  
CSR_BUSY = 1  
Figure 6.1 Switch Fabric CSR Write Access Flow Diagram  
6.2.2  
Switch Fabric CSR Reads  
To perform a read of an individual switch fabric register, the read cycle must be initiated by performing  
a single write to the Switch Fabric CSR Interface Command Register (SWITCH_CSR_CMD) with  
CSR_BUSY (bit 31) set, the CSR_ADDRESS field (bits 15:0) set to the desired register address, the  
R_nW (bit 30) set, and the AUTO_INC and AUTO_DEC fields cleared. Valid data is available for  
reading when the CSR_BUSY bit is cleared, indicating that the data can be read from the Switch Fabric  
CSR Interface Data Register (SWITCH_CSR_DATA).  
A second read method may be used which utilizes the auto increment/decrement function of the Switch  
Fabric CSR Interface Command Register (SWITCH_CSR_CMD) for reading sequential register  
addresses. When using this method, the Switch Fabric CSR Interface Command Register  
(SWITCH_CSR_CMD) must first be written with the auto increment(AUTO_INC) or auto  
decrement(AUTO_DEC) bit set, the CSR_ADDRESS field written with the desired register address,  
and the R_nW bit set. The completion of a read cycle is indicated by the clearing of the CSR_BUSY  
bit, at which time the data can be read from the Switch Fabric CSR Interface Data Register  
(SWITCH_CSR_DATA). When the data is read, the address in the Switch Fabric CSR Interface  
Command Register (SWITCH_CSR_CMD) is incremented or decremented accordingly, and another  
read cycle is started automatically. The user should clear the AUTO_INC and AUTO_DEC bits before  
reading the last data to avoid an unintended read cycle.  
Figure 6.2 illustrates the process required to perform a switch fabric CSR read. The minimum wait  
periods as specified in Table 8.1, “Read After Write Timing Rules,” on page 101 are required where  
noted.  
SMSC LAN9312  
Revision 1.2 (04-08-08)  
DATA5S7HEET  
 复制成功!