Buffer Manager Port 1 Ingress Rate Drop Count Register (BM_RATE_DRP_CNT_SRC_1)
Register #:
1C17h
Size:
32 bits
This register counts the number of packets received on Port 1 that were dropped by the Buffer
Manager due to ingress rate limit discarding (Red and random Yellow dropping).
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
Dropped Count
RC
00000000h
These bits count the number of dropped packets received on Port 1 and is
cleared when read.
Note:
This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.