Table 20 - Description of Command Symbols
DESCRIPTION
SYMBOL
GAP
NAME
Alters Gap 2 length when using Perpendicular Mode.
GPL
Gap Length
The Gap 3 size. (Gap 3 is the space between sectors excluding
the VCO synchronization field).
H/HDS
HLT
Head Address
Selected head: 0 or 1 (disk side 0 or 1) as encoded in the sector
ID field.
Head Load Time The time interval that FDC waits after loading the head and before
initializing a read or write operation. Refer to the Specify
command for actual delays.
HUT
Head Unload
Time
The time interval from the end of the execution phase (of a read or
write command) until the head is unloaded. Refer to the Specify
command for actual delays.
LOCK
Lock defines whether EFIFO, FIFOTHR and PRETRK parameters
of the CONFIGURE COMMAND can be reset to their default
values by a "Software Reset". (A reset caused by writing to the
appropriate bits of either tha DSR or DOR).
MFM
MT
MFM/FM Mode
Selector
A “1” selects the double density (MFM) mode. A “0” selects single
density (FM) mode.
Multi-Track
Selector
When set, this flag selects the multi-track operating mode. In this
mode, the FDC treats a complete cylinder under head 0 and 1 as
a single track. The FDC operates as this expanded track started
at the first sector under head 0 and ended at the last sector under
head 1. With this flag set, a multitrack read or write operation will
automatically continue to the first sector under head 1 when the
FDC finishes operating on the last sector under head 0.
40