欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37CXFR 参数 Datasheet PDF下载

FDC37CXFR图片预览
型号: FDC37CXFR
PDF下载: 下载PDF文件 查看货源
内容描述: 即插即用兼容超I / O控制器,提供快速IR [Plug and Play Compatible Ultra I/O Controller with Fast IR]
分类和应用: 控制器
文件页数/大小: 258 页 / 898 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37CXFR的Datasheet PDF文件第35页浏览型号FDC37CXFR的Datasheet PDF文件第36页浏览型号FDC37CXFR的Datasheet PDF文件第37页浏览型号FDC37CXFR的Datasheet PDF文件第38页浏览型号FDC37CXFR的Datasheet PDF文件第40页浏览型号FDC37CXFR的Datasheet PDF文件第41页浏览型号FDC37CXFR的Datasheet PDF文件第42页浏览型号FDC37CXFR的Datasheet PDF文件第43页  
is issued. The user sends a Sense Interrupt  
Status command which returns an invalid  
COMMAND SET/DESCRIPTIONS  
command error.  
Refer to Table 19 for  
Commands can be written whenever the FDC is  
in the command phase. Each command has a  
unique set of needed parameters and status  
results. The FDC checks to see that the first  
byte is a valid command and, if valid, proceeds  
with the command. If it is invalid, an interrupt  
explanations of the various symbols used. Table  
21 lists the required parameters and the results  
associated with each command that the FDC is  
capable of performing.  
Table 20 - Description of Command Symbols  
NAME DESCRIPTION  
Cylinder Address The currently selected address; 0 to 255.  
Data Pattern The pattern to be written in each sector data field during  
SYMBOL  
C
D
formatting.  
D0, D1, D2, Drive Select 0-3  
D3  
Designates which drives are perpendicular drives on the  
Perpendicular Mode Command. A "1" indicates a perpendicular  
drive.  
DIR  
Direction Control If this bit is 0, then the head will step out from the spindle during a  
relative seek. If set to a 1, the head will step in toward the spindle.  
DS1  
DS0  
DRIVE  
DS0, DS1  
Disk Drive Select  
0
0
1
1
0
1
0
1
drive 0  
drive 1  
drive 2  
drive 3  
DTL  
Special Sector  
Size  
By setting N to zero (00), DTL may be used to control the number  
of bytes transferred in disk read/write commands. The sector size  
(N = 0) is set to 128. If the actual sector (on the diskette) is larger  
than DTL, the remainder of the actual sector is read but is not  
passed to the host during read commands; during write  
commands, the remainder of the actual sector is written with all  
zero bytes. The CRC check code is calculated with the actual  
sector. When N is not zero, DTL has no meaning and should be  
set to FF HEX.  
EC  
Enable Count  
Enable FIFO  
When this bit is "1" the "DTL" parameter of the Verify command  
becomes SC (number of sectors per track).  
EFIFO  
EIS  
This active low bit when a 0, enables the FIFO. A "1" disables the  
FIFO (default).  
Enable Implied  
Seek  
When set, a seek operation will be performed before executing any  
read or write command that requires the C parameter in the  
command phase. A "0" disables the implied seek.  
EOT  
End of Track  
The final sector number of the current track.  
39  
 复制成功!