欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37N3869 参数 Datasheet PDF下载

FDC37N3869图片预览
型号: FDC37N3869
PDF下载: 下载PDF文件 查看货源
内容描述: 3.3V超级I / O控制器,红外支持 [3.3V SUPER I/O CONTROLLER WITH INFRARED SUPPORT]
分类和应用: 控制器
文件页数/大小: 136 页 / 718 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37N3869的Datasheet PDF文件第43页浏览型号FDC37N3869的Datasheet PDF文件第44页浏览型号FDC37N3869的Datasheet PDF文件第45页浏览型号FDC37N3869的Datasheet PDF文件第46页浏览型号FDC37N3869的Datasheet PDF文件第48页浏览型号FDC37N3869的Datasheet PDF文件第49页浏览型号FDC37N3869的Datasheet PDF文件第50页浏览型号FDC37N3869的Datasheet PDF文件第51页  
WRITE DELETED DATA  
This command is almost the same as the Write Data command except that a Deleted Data Address Mark is written at  
the beginning of the Data Field instead of the normal Data Address Mark. This command is typically used to mark a  
bad sector containing an error on the floppy disk.  
VERIFY  
The Verify command is used to verify the data stored on a disk. This command acts exactly like a Read Data  
command except that no data is transferred to the host. Data is read from the disk and CRC is computed and  
checked against the previously-stored value.  
Because data is not transferred to the host, TC (pin 25) cannot be used to terminate this command. By setting the  
EC bit to “1”, an implicit TC will be issued to the FDC. This implicit TC will occur when the SC value has  
decremented to 0 (an SC value of 0 will verify 256 sectors). This command can also be terminated by setting the EC  
bit to “0” and the EOT value equal to the final sector to be checked. If EC is set to “0”, DTL/SC should be  
programmed to 0FFH. Refer to Table 38 and Table 39 for information concerning the values of MT and EC versus  
SC and EOT value.  
Definitions:  
# Sectors Per Side = Number of formatted sectors per each side of the disk.  
# Sectors Remaining = Number of formatted sectors left which can be read, including side 1 of the disk if MT is set to  
“1”.  
Table 39 - Verify Command Result Phase Table  
MT  
EC  
SC/EOT VALUE  
TERMINATION RESULT  
0
0
SC = DTL  
EOT £ # Sectors Per Side  
SC = DTL  
EOT > # Sectors Per Side  
SC £ # Sectors Remaining AND  
EOT £ # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
SC = DTL  
EOT £ # Sectors Per Side  
SC = DTL  
EOT > # Sectors Per Side  
SC £ # Sectors Remaining AND  
EOT £ # Sectors Per Side  
SC > # Sectors Remaining OR  
EOT > # Sectors Per Side  
Success Termination  
Result Phase Valid  
0
0
0
1
1
1
1
0
1
1
0
0
1
1
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Successful Termination  
Result Phase Valid  
Unsuccessful Termination  
Result Phase Invalid  
Note: If MT is set to “1” and the SC value is greater than the number of remaining formatted sectors on Side 0,  
verifying will continue on Side 1 of the disk.  
SMSC DS – FDC37N3869  
Page 47  
Rev. 10/25/2000  
 复制成功!