欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37M607 参数 Datasheet PDF下载

FDC37M607图片预览
型号: FDC37M607
PDF下载: 下载PDF文件 查看货源
内容描述: 增强的超级I / O控制器,红外支持 [ENHANCED SUPER I/O CONTROLLER WITH INFRARED SUPPORT]
分类和应用: 控制器
文件页数/大小: 182 页 / 634 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37M607的Datasheet PDF文件第95页浏览型号FDC37M607的Datasheet PDF文件第96页浏览型号FDC37M607的Datasheet PDF文件第97页浏览型号FDC37M607的Datasheet PDF文件第98页浏览型号FDC37M607的Datasheet PDF文件第100页浏览型号FDC37M607的Datasheet PDF文件第101页浏览型号FDC37M607的Datasheet PDF文件第102页浏览型号FDC37M607的Datasheet PDF文件第103页  
Table 43 - Forward Channel Commands (HostAck Low)  
Reverse Channel Commands (PeripAck Low)  
D7  
D[6:0]  
0
Run-Length Count (0-127)  
(mode 0011 0X00 only)  
1
Channel Address (0-127)  
Pin Definition  
Data Compression  
The drivers for nStrobe, nAutoFd, nInit and  
nSelectIn are open-collector in mode 000 and  
are push-pull in all other modes.  
The ECP port supports run length encoded  
(RLE) decompression in hardware and can  
transfer compressed data to a peripheral. Run  
length encoded (RLE) compression in hardware  
is not supported. To transfer compressed data  
in ECP mode, the compression count is written  
to the ecpAFifo and the data byte is written to  
the ecpDFifo.  
ISA Connections  
The interface can never stall causing the host to  
hang. The width of data transfers is strictly  
controlled on an I/O address basis per this  
specification. All FIFO-DMA transfers are byte  
wide, byte aligned and end on a byte boundary.  
(The PWord value can be obtained by reading  
Configuration Register A, cnfgA, described in  
the next section). Single byte wide transfers  
are always possible with standard or PS/2  
mode using program control of the control  
signals.  
Compression is accomplished by counting  
identical bytes and transmitting an RLE byte  
that indicates how many times the next byte is  
to be repeated. Decompression simply  
intercepts the RLE byte and repeats the  
following byte the specified number of times.  
When a run-length count is received from a  
peripheral, the subsequent data byte is  
replicated the specified number of times. A  
run-length count of zero specifies that only one  
byte of data is represented by the next data  
byte, whereas a run-length count of 127  
indicates that the next byte should be expanded  
to 128 bytes. To prevent data expansion,  
however, run-length counts of zero should be  
avoided.  
Interrupts  
The interrupts are enabled by serviceIntr in the  
ecr register.  
serviceIntr = 1 Disables the DMA and all of the  
service interrupts.  
serviceIntr = 0 Enables the selected interrupt  
condition. If the interrupting  
condition is valid, then the  
interrupt  
is  
generated  
immediately when this bit is  
changed from a “1” to a “0”.  
This  
can  
occur  
during  
Programmed I/O if the number  
of bytes removed or added  
99  
 复制成功!