1: The FIFO is completely empty.  
0: The FIFO contains at least 1 byte of data.  
Table 42A - Extended Control Register  
R/W  
MODE  
000: Standard Parallel Port Mode . In this mode the FIFO is reset and common collector drivers  
are used on the control lines (nStrobe, nAutoFd, nInit and nSelectIn). Setting the direction  
bit will not tri-state the output drivers in this mode.  
001: PS/2 Parallel Port Mode. Same as above except that direction may be used to tri-state the  
data lines and reading the data register returns the value on the data lines and not the  
value in the data register. All drivers have active pull-ups (push-pull).  
010: Parallel Port FIFO Mode. This is the same as 000 except that bytes are written or DMAed to  
the FIFO. FIFO data is automatically transmitted using the standard parallel port protocol.  
Note that this mode is only useful when direction is 0. All drivers have active pull-ups  
(push-pull).  
011: ECP Parallel Port Mode. In the forward direction (direction is 0) bytes placed into the  
ecpDFifo and bytes written to the ecpAFifo are placed in a single FIFO and transmitted  
automatically to the peripheral using ECP Protocol. In the reverse direction (direction is 1)  
bytes are moved from the ECP parallel port and packed into bytes in the ecpDFifo. All  
drivers have active pull-ups (push-pull).  
100: Selects EPP Mode: In this mode, EPP is selected if the EPP supported option is selected in  
configuration register L3-CRF0. All drivers have active pull-ups (push-pull).  
101: Reserved  
110: Test Mode. In this mode the FIFO may be written and read, but the data will not be  
transmitted on the parallel port. All drivers have active pull-ups (push-pull).  
111: Configuration Mode. In this mode the confgA, confgB registers are accessible at 0x400 and  
0x401. All drivers have active pull-ups (push-pull).  
Table 42B  
CONFIG REG B  
Table 42C  
CONFIG REG B  
IRQ SELECTED  
BITS 5:3  
110  
DMA SELECTED  
BITS 2:0  
011  
15  
3
14  
11  
101  
100  
2
1
010  
001  
10  
011  
All Others  
000  
9
010  
7
5
001  
111  
All Others  
000  
96  