 浏览型号FDC37B78X_07的Datasheet PDF文件第105页浏览型号FDC37B78X_07的Datasheet PDF文件第106页浏览型号FDC37B78X_07的Datasheet PDF文件第107页浏览型号FDC37B78X_07的Datasheet PDF文件第108页浏览型号FDC37B78X_07的Datasheet PDF文件第110页浏览型号FDC37B78X_07的Datasheet PDF文件第111页浏览型号FDC37B78X_07的Datasheet PDF文件第112页浏览型号FDC37B78X_07的Datasheet PDF文件第113页  
NOTE1: The Parallel Port Control register reads as “Cable Not Connected” when the Parallel Port FDC  
is enabled; i.e., STROBE = AUTOFD = SLC = 0 and nINIT = 1.  
TABLE 47 - FDC PARALLEL PORT PINS  
SPP MODE PIN DIRECTION  
FDC MODE  
PIN DIRECTION  
nSTROBE  
I/O  
I/O  
I/O  
I/O  
I/O  
I/O  
I/O  
I/O  
I/O  
I
(nDS0)  
I/(O) Note1  
PD0  
nINDEX  
nTRK0  
nWP  
I
PD1  
I
PD2  
I
PD3  
nRDATA  
nDSKCHG  
-
I
PD4  
I
PD5  
-
PD6  
(nMTR0)  
-
I/(O) Note1  
PD7  
-
nACK  
BUSY  
PE  
nDS1  
O
O
O
O
O
O
O
O
I
nMTR1  
nWDATA  
nWGATE  
DRVDEN0  
nHDSEL  
nDIR  
I
SLCT  
nALF  
nERROR  
nINIT  
nSLCTIN  
I
I/O  
I
I/O  
I/O  
nSTEP  
Note 1: These pins are outputs in mode PPFD2, inputs in mode PPFD1.  
Refer to Force Write Protect in the Floppy Disk Controller section for information on the Floppy disk  
Controller Force Write Protect function.  
POWER MANAGEMENT  
Power management capabilities are provided for  
the following logical devices: floppy disk, UART 1,  
UART 2 and the parallel port. For each logical  
device, two types of power management are  
provided; direct powerdown and auto powerdown.  
Auto Power Management is enabled by CR23-B0.  
When set, this bit allows FDC to enter powerdown  
when all of the following conditions have been met:  
1. The motor enable pins of register 3F2H are  
inactive (zero).  
FDC Power Management  
2. The part must be idle; MSR=80H and INT = 0  
(INT may be high even if MSR = 80H due to  
polling interrupts).  
Direct power management is controlled by CR22.  
Refer to CR22 for more information.  
3. The head unload timer must have expired.  