1. ECP is not enabled in the configuration
registers.
UART Power Management
Direct power management is controlled by CR22.
Refer to CR22 for more information.
2
SPP, PS/2 Parallel port or EPP mode is
selected through ecr while in ECP mode.
Auto Power Management is enabled by CR23-B4
and B5. When set, these bits allow the following
auto power management operations:
Exit Auto Powerdown
The parallel port logic can change powerdown
modes when the ECP mode is changed through
the ecr register or when the parallel port mode is
changed through the configuration registers.
1. The transmitter enters auto powerdown when
the transmit buffer and shift register are
empty.
2. The receiver enters powerdown when the
following conditions are all met:
VBAT Support
This chip requires a (TBD) MicroAmp battery
supply (VBAT) to provide battery backed up
registers. These registers retain the contents of
the general purpose registers and wake-up event
registers. The RTC and CMOS registers are
also battery backed up. Note: The configuration
of the Consumer IR wake-up functionality is not
battery backed-up.
A. Receive FIFO is empty
B. The receiver is waiting for a start bit.
Note:
While in powerdown the Ring Indicator
interrupt is still valid and transitions when
the RI input changes.
Exit Auto Powerdown
V
TR Support
The transmitter exits powerdown on a write to the
XMIT buffer. The receiver exits auto powerdown
when RXDx changes state.
The FDC37B78x requires a 25 mA trickle supply
(VTR to provide sleep current for the
)
programmable wake-up events in the Soft Power
Management logic, SCI, PME and SMI interfaces
when VCC is removed. If the FDC37B78x is not
intended to provide wake-up capabilities on
Parallel Port
Direct power management is controlled by CR22.
Refer to CR22 for more information.
standby current, VTR can be connected to VCC
.
VTR powers the Consumer IR receiver, IR
interface, the CIR run-time registers, the PME
configuration registers, and the PME interface.
The VTR pin generates a VTR Power-on-Reset
Auto Power Management is enabled by CR23-B3.
When set, this bit allows the ECP or EPP logical
parallel port blocks to be placed into powerdown
when not being used.
signal to initialize certain components.
All
wakeup event registers and related logic are
battery backed-up to retain the configuration of
The EPP logic is in powerdown under any of the
following conditions:
the wakeup events upon a power loss (i.e., VCC
=
0 V and VTR = 0 V). These registers are reset on
a VBAT POR.
1. EPP is not enabled in the configuration
registers.
2. EPP is not selected through ecr while in ECP
mode.
The ECP logic is in powerdown under any of the
following conditions:
115