Fan Control Device with High Frequency PWM and Temperature Monitors  
Datasheet  
8.2.12  
Registers 54-5Bh: Fan Tachometer Low Limit  
Table 8.21 Registers 54-5Bh: Fan Tachometer Low Limit  
Register  
Address  
Read/  
Write  
Bit 7  
(MSb)  
Bit 0  
(LSb)  
Default  
Value  
Register Name  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
54h  
55h  
56h  
57h  
58h  
59h  
5Ah  
5Bh  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Tach1 Minimum LSB  
Tach1 Minimum MSB  
Tach2 Minimum LSB  
Tach2 Minimum MSB  
Tach3 Minimum LSB  
Tach3 Minimum MSB  
Tach4 Minimum LSB  
Tach4 Minimum MSB  
7
15  
7
6
14  
6
5
13  
5
4
12  
4
3
11  
3
2
10  
2
1
9
1
9
1
9
1
9
0
8
0
8
0
8
0
8
FFh  
FFh  
FFh  
FFh  
FFh  
FFh  
FFh  
FFh  
15  
7
14  
6
13  
5
12  
4
11  
3
10  
2
15  
7
14  
6
13  
5
12  
4
11  
3
10  
2
15  
14  
13  
12  
11  
10  
Setting the Lock bit has no effect on these registers.  
The Fan Tachometer Low Limit registers indicate the tachometer reading that, if exceeded, the  
corresponding bit will be set in the Interrupt Status Register 2 register. This register represents a  
number of clock counts between the programmed number of tach edges and therefore as the number  
increases, the effective RPM that it represents will decrease. The limit represents a fixed fan speed  
(though the TACH measurement options may limit fan speeds that can be measured). See  
Section 8.2.3 for a description of the TACH data formatting.  
In Auto Fan Control mode, the fan can run at high speeds (100% duty cycle), so care should be taken  
in software to ensure that the limit is low enough not to cause sporadic alerts. Note that an interrupt  
status event will be generated when the tachometer reading is greater than the minimum tachometer  
limit.  
The fan tachometer will not cause a bit to be set in the interrupt status register if the current value in  
the associated Current PWM Duty registers is 00h or if the PWM is disabled via the PWM  
Configuration Register.  
Interrupts will never be generated for a fan if its tachometer minimum is set to FFFFh.  
8.2.13  
Registers 5C-5Eh: PWM Configuration  
Table 8.22 Registers 5C-5Eh: PWM Configuration  
Register  
Address  
Read/  
Write  
Bit 7  
(MSb)  
Bit 0  
(LSb)  
Default  
Value  
Register Name  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
5Ch  
5Dh  
5Eh  
R/W  
R/W  
R/W  
PWM 1 Configuration  
PWM 2 Configuration  
PWM 3 Configuration  
ZON2  
ZON2  
ZON2  
ZON1  
ZON1  
ZON1  
ZON0  
ZON0  
ZON0  
INV  
INV  
INV  
RES  
RES  
RES  
SPIN2  
SPIN2  
SPIN2  
SPIN1  
SPIN1  
SPIN1  
SPIN0  
SPIN0  
SPIN0  
62h  
62h  
62h  
These registers become read only when the Lock bit is set. Any further attempts to write to these  
registers shall have no effect.  
Bits [7:5] Zone/Mode  
Bits [7:5] of the PWM Configuration registers associate each PWM with a temperature sensor.  
SMSC EMC2300  
Revision 0.2 (06-14-06)  
DATA5S9HEET