Fan Control Device with High Frequency PWM and Temperature Monitors  
Datasheet  
Chapter 6 Hardware Monitoring  
The following sub-sections describe the EMC2300 Hardware Monitoring features.  
6.1  
Input Monitoring  
The EMC2300 device’s monitoring function is started by writing a ‘1’ to the START bit in the  
Ready/Lock/Start Register (0x40). Measured values from the analog inputs and temperature sensors  
are stored in Reading Registers. The values in the reading registers can be accessed via the SMBus  
interface. These values are compared to the programmed limits in the Limit Register. The out-of-limit  
and diode fault conditions are stored in the Interrupt Status Registers.  
6.2  
Resetting the EMC2300  
6.2.1  
Power-On Reset  
All the registers in the Hardware Monitor Block, except the reading registers, reset to a default value  
when power is applied to the block. The default state of the register is shown in the table in the  
Register Summary subsection. The default state of Reading Registers are not shown because these  
registers have indeterminate power on values.  
Note: Usually the first action after power up is to write limits into the Limit Registers.  
6.2.2  
Soft Reset (Initialization)  
Setting bit 7 of the CONF register performs a soft reset. This bit is self-clearing. Soft Reset performs  
reset on all the registers except the Reading Registers.  
6.3  
Monitoring Modes  
The Hardware Monitor Block supports two Monitoring modes: Continuous Mode and Cycle Mode.  
These modes are selected using bit 1 of the Special Function Register (7Ch). The following  
subsections contain a description of these monitoring modes.  
The hardware monitor conversion clock is 45KHz ± 10%. Temperature conversions take 96 clocks,  
each (2.133ms nom.); voltage conversions take 68 clocks, each (1.511ms nom). The time to complete  
a conversion cycle depends upon the number of inputs in the conversion sequence to be measured  
(see Table 6.3, “ADC Conversion Sequence,” on page 22) and the amount of averaging per input,  
which is selected using the AVG[2:0] bits in the Special Function register (see Register 7Ch: Special  
Function Register on page 67).  
For each mode, there are four options for the number of measurements that are averaged for each  
temperature and voltage reading. These options are selected using bits[7:5] of the Special Function  
register (7Ch). These bits are defined as follows:  
Bits [7:5] AVG[2:0]  
The AVG[2:0] bits determine the amount of averaging for each of the measurements that are performed  
by the hardware monitor before the reading registers are updated (Table 6.1). The AVG[2:0] bits are  
priority encoded where the most significant bit has highest priority. For example, when the AVG2 bit is  
asserted, 32 averages will be performed for each measurement before the reading registers are  
updated regardless of the state of the AVG[1:0] bits.  