Fan Control Device with High Frequency PWM and Temperature Monitors  
Datasheet  
According to SMBus specification, v2.0 devices in a transfer can abort the transfer in progress and  
release the bus when any single clock low interval exceeds 25ms (TTIMEOUT, MIN). Devices that have  
detected this condition must reset their communication and be able to receive a new START condition  
no later than 35ms (TTIMEOUT, MAX).  
Note: Some simple devices do not contain a clock low drive circuit; this simple kind of device typically  
may reset its communications port after a start or stop condition  
5.7  
Stretching the SCLK Signal  
The EMC2300 supports stretching of the SCLK by other devices on the SMBus but will not stretch the  
SCLK itself.  
5.8  
5.9  
5.10  
SMBus Timing  
The SMBus Slave Interface complies with the SMBus AC Timing Specification. See the SMBus timing  
diagram shown in the section titled Section 9.2, "SMBus Interface," on page 76.  
Bus Reset Sequence  
The SMBus Slave Interface will reset and return to the idle state upon a START field followed  
immediately by a STOP field.  
SMBus Alert Response Address  
The EMC2300 device responds to the SMBus Alert Response Address, 0001 100, if the INTEN bit  
(register 7Ch bit 2) is set and one or more status events bits are high. The interrupt signal (INT#),  
which can be enabled on either the PWM2 or TACH3 pins, can be used as the SMBALERT#. See the  
section describing the Interrupt Status Registers on page 23 and the section describing the Interrupt  
Pin on page 25 for more details on interrupts.  
The device can signal the host that it wants to talk by pulling the SMBALERT# low, if a status bit is  
set in one of the interrupt status registers and properly enabled onto the INT# pin. The host processes  
the interrupt and simultaneously accesses all SMBALERT# devices through a modified Receive Byte  
operation with the Alert Response Address (ARA).  
The EMC2300 device, which pulled SMBALERT# low, will acknowledge the Alert Response Address  
and respond with its device address. The 7-bit device address provided by the EMC2300 device is  
placed in the 7 most significant bits of the byte. The eighth bit can be a zero or one.  
Table 5.4 Modified SMBus Receive Byte Protocol Response to ARA  
ALERT  
RESPONSE  
ADDRESS  
EMC2300 SLAVE  
FIELD:  
Bits:  
START  
RD  
ACK  
ADDRESS  
NACK  
STOP  
1
7
1
1
8
1
1
After acknowledging the slave address, the EMC2300 device will disengage the SMBALERT# pull-down  
by clearing the INT enable bit. If the condition that caused the interrupt remains, the Fan Control device  
will reassert the SMBALERT# on the next monitoring cycle, provided the INT enable bit has been set  
back to ‘1’ by software.  
Note: The INT# signal is an alternate function on the PWM2 and TACH3 pins. The EMC2300 device  
will respond to the SMBus Alert Response address even if the INT# signal is not selected as  
the alternate function on one of these pins as long as the following conditions exist: the INTEN  
Revision 0.2 (06-14-06)  
SMSC EMC2300  
DATA1S8HEET