Dual RPM-Based PWM Fan Controller with Hardware Thermal Shutdown  
Datasheet  
Table 6.38 DRIVE_FAIL_CNT[1:0] Bit Decode  
DRIVE_FAIL_CNT[1:0]  
1
0
NUMBER OF UPDATE PERIODS  
0
0
1
1
0
1
0
1
Disabled - the Drive Fail detection circuitry is  
disabled (default)  
16 - the Drive Fail detection circuitry will count for 16  
update periods  
32 - the Drive Fail detection circuitry will count for 32  
update periods  
64 - the Drive Fail detection circuitry will count for 64  
update periods  
Bit 5 - NOKICKx - Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of  
the programmed spin up time before driving it at the programmed level.  
„
‘0’ (default) - The Spin Up Routine will drive the fan driver to 100% for 1/4 of the programmed spin  
up time before reverting to the programmed spin level.  
„
‘1’ - The Spin Up Routine will not drive the fan driver to 100%. It will set the drive at the  
programmed spin level for the entire duration of the programmed spin up time.  
Bits 4 - 2 - SPIN_LVL[2:0] - Determines the final drive level that is used by the Spin Up Routine as  
shown in Table 6.39.  
Table 6.39 Spin Level  
SPIN_LVL[2:0]  
2
1
0
SPIN UP DRIVE LEVEL  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
30%  
35%  
40%  
45%  
50%  
55%  
60% (default)  
65%  
Bit 1 -0 - SPINUP_TIME[1:0] - determines the maximum Spin Time that the Spin Up Routine will run  
for (see Section 6.9). If a valid tachometer measurement is not detected before the Spin Time has  
elapsed, then an interrupt will be generated. When the RPM based Fan Speed Control Algorithm is  
active, the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt.  
The Spin Time is set as shown in Table 6.40.  
Revision 1.74 (05-08-08)  
SMSC EMC2104  
DATA7S0HEET