 浏览型号COM20020I3V-HT的Datasheet PDF文件第57页浏览型号COM20020I3V-HT的Datasheet PDF文件第58页浏览型号COM20020I3V-HT的Datasheet PDF文件第59页浏览型号COM20020I3V-HT的Datasheet PDF文件第60页浏览型号COM20020I3V-HT的Datasheet PDF文件第61页浏览型号COM20020I3V-HT的Datasheet PDF文件第62页浏览型号COM20020I3V-HT的Datasheet PDF文件第63页浏览型号COM20020I3V-HT的Datasheet PDF文件第65页  
5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM  
The EF bit also controls the resolution of the following issues from the COM20020I Rev. B:  
A) Network MAP Generation  
Tentative ID is used for generating the Network MAP, but it sometimes detects a non-existent node. Every time the  
Tentative-ID register is written, the effect of the old Tentative-ID remains active for a while, which results in an  
incorrect network map. It can be avoided by a carefully coded software routine, but this requires the programmer to  
have deep knowledge of how the COM20020I works. Duplicate-ID is mainly used for generating the Network MAP.  
This has the same issue as Tentative-ID.  
A minor logic change clears all the remaining effects of the old Tentative-ID and the old Duplicate-ID, when the  
COM20020I detects a write operation to Tentative-ID or Node-ID register. With this change, programmers can use  
the Tentative-ID or Duplicate-ID for generating the network MAP without any issues. This change is Enabled/Disabled  
by the EF bit.  
B) Mask Register Reset  
The Mask register is reset by a soft reset in the COM20020I Rev. A, but is not reset in Rev. B. The Mask register is  
related to the Status and Diagnostic register, so it should be reset by a soft reset. Otherwise, every time the soft  
reset happens, the COM20020I Rev. B generates an unnecessary interrupt since the status bits RI and TA are back  
to one by the soft reset.  
This is resolved by changing the logic to reset the Mask register both by the hard reset and by the soft reset. The soft  
reset is activated by the Node-ID register going to 00h or by the RESET bit going to High in the Configuration  
register. This solution is Enabled/Disabled by the EF bit.  