 浏览型号COM20020I3V-HT的Datasheet PDF文件第25页浏览型号COM20020I3V-HT的Datasheet PDF文件第26页浏览型号COM20020I3V-HT的Datasheet PDF文件第27页浏览型号COM20020I3V-HT的Datasheet PDF文件第28页浏览型号COM20020I3V-HT的Datasheet PDF文件第30页浏览型号COM20020I3V-HT的Datasheet PDF文件第31页浏览型号COM20020I3V-HT的Datasheet PDF文件第32页浏览型号COM20020I3V-HT的Datasheet PDF文件第33页  
5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM  
Table 5 - Diagnostic Status Register  
SYMBOL DESCRIPTION  
BIT  
BIT NAME  
7
My  
MY-  
This bit, if high, indicates that a past reconfiguration was caused by  
this node. It is set when the Lost Token Timer times out, and  
should be typically read following an interrupt caused by RECON.  
Refer to the Improved Diagnostics section for further detail.  
Reconfiguration  
RECON  
6
Duplicate ID  
DUPID  
This bit, if high, indicates that the value in the Node ID Register  
matches both Destination ID characters of the token and a  
response to this token has occurred. Trailing zero's are also  
verified. A logic "1" on this bit indicates a duplicate Node ID, thus  
the user should write a new value into the Node ID Register. This  
bit is only useful for duplicate ID detection when the device is off  
line, that is, when the transmitter is disabled. When the device is  
on line this bit will be set every time the device gets the token. This  
bit is reset automatically upon reading the Diagnostic Status  
Register. Refer to the Improved Diagnostics section for further  
detail.  
5
4
3
Receive  
Activity  
RCVACT This bit, if high, indicates that data activity (logic "1") was detected  
on the RXIN pin of the device. Refer to the Improved Diagnostics  
section for further detail.  
Token Seen  
TOKEN  
This bit, if high, indicates that a token has been seen on the  
network, sent by a node other than this one. Refer to the Improved  
Diagnostic section for further detail.  
Excessive NAK  
EXCNAK This bit, if high, indicates that either 128 or 4 Negative  
Acknowledgements have occurred in response to the Free Buffer  
Enquiry. This bit is cleared upon the "POR Clear Flags" command.  
Reading the Diagnostic Status Register does not clear this bit.  
This bit, when set, will cause an interrupt if the corresponding bit in  
the IMR is also set. Refer to the Improved Diagnostics section for  
further detail.  
2
1
Tentative ID  
New Next ID  
TENTID  
This bit, if high, indicates that a response to a token whose DID  
matches the value in the Tentative ID Register has occurred. The  
second DID and the trailing zero's are not checked. Since each  
node sees every token passed around the network, this feature  
can be used with the device on-line in order to build and update a  
network map. Refer to the Improved Diagnostics section for further  
detail.  
NEW  
This bit, if high, indicates that the Next ID Register has been  
updated and that a node has either joined or left the network.  
Reading the Diagnostic Status Register does not clear this bit. This  
bit, when set, will cause an interrupt if the corresponding bit in the  
IMR is also set. The bit is cleared by reading the Next ID Register.  
NXTID  
1,0 (Reserved)  
These bits are undefined.  
SMSC COM20020I 3.3V  
Page 29  
Revision 12-06-06  
DATASHEET  