iPAC™ FEM FOR QUAD-BAND GSM / GPRS  
DATA SHEET • SKY77500  
Table 4. SKY77500 Electrical Specifications (1) (9 of 9)  
PCS1900 Mode (f = 1850 to 1910 MHz and PIN = 0 to 6 dBm) [continued]  
Parameter  
Symbol  
Test Condition  
Min.  
Typ.  
Max.  
Units  
All combinations of the following parameters:  
(3)  
VAPC = controlled  
Spurious  
Spur  
PIN = min. to max.  
No parasitic oscillation > –36 dBm  
VCC = 2.9 V to 4.8 V  
Load VSWR = 12:1, all phase angles  
All combinations of the following parameters:  
(3)  
VAPC = controlled  
Load mismatch  
Load  
PIN = min. to max.  
No module damage or permanent degradation  
VCC = 2.9 V to 4.8 V  
Load VSWR = 20:1, all phase angles  
At fO + 20 MHz (1930 to 1990 MHz)  
RBW = 100 kHz  
VCC = 3.5 V  
–89  
–80  
dBm  
0 dBm POUT 30 dBm  
TCASE = +25 °C  
Rx Band Spurious  
RX_SPUR  
At 869 to 894 MHz  
RBW = 100 kHz  
VCC = 3.5 V  
0 dBm POUT 30 dBm  
TCASE = +25 °C  
35  
50  
–87  
Power control dynamic range  
PCDR  
PCV  
VCC = 3.5 V  
dB  
dB  
Control level 0–8 (3.2 V  
VCC 4.5 V)  
POUT +14 to +30 dBm, +25 °C  
POUT +14 to +30 dBm  
POUT +4 to +12 dBm, +25 °C  
POUT +4 to +12 dBm  
POUT 0 to +2 dBm, +25 °C  
POUT 0 to +2 dBm  
–1.0  
–1.8  
–1.9  
–3.3  
–3.0  
–4.5  
+1.0  
+1.8  
+1.9  
+3.3  
+3.0  
+4.5  
Power control  
variation  
Control level 9–13  
Control level 14–15  
Power control slope  
Closed loop bandwidth  
Loop phase margin  
PCS  
BCL  
PM  
0 to 30 dBm  
VAPC = 1.0 V  
VAPC = 1.0 V  
75  
500  
550  
dB/V  
kHz  
deg.  
PCS 1900 RECEIVE (f = 1930 to 1990 MHz) Mode = DCS_RX  
Frequency range  
f
1930  
1.3  
1990  
1.5  
MHz  
dB  
(5)  
Insertion Loss, ANT-to-DCS_RX  
IL DCS_RX  
TCASE = +25 °C  
(5)  
VSWR ANT, DCS_RX  
ΓIN, ΓOUT  
1.2:1  
1.5:1  
(1)  
Unless specified otherwise:  
TCASE = –20 °C to max. operating temperature (see Table 2), RL = 50 , pulsed operation with pulse width 1154 µs and duty cycle 2:8, VCC = 2.9 V to 4.8 V.  
(2)  
(3)  
(4)  
(5)  
(6)  
ICC = 0A to xA, where x = current at POUT = 33 dBm, 50 load, and VCC = 3.5 V.  
ICC = 0A to xA, where x = current at POUT = 30 dBm, 50 load, and VCC = 3.5 V.  
This device has an Open Loop mode that allows bypassing the internal PAC circuitry. See the Technical Information section at end of this document for further information.  
Terminate all unused RF ports with 50 load.  
BS_1, BS_2, TX_RX, and PAC_EN inputs have active 200 kpulldowns to ground.  
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com  
103146A • Skyworks Proprietary information. • Products and product information are subject to change without notice. • May 16, 2005  
11