Si3056
Si3018/19/10
Register 45. Programmable Hybrid Register 1
Bit
D7
D6
D5
D4
D3
HYB1 [7:0]
R/W
D2
D1
D0
Name
Type
Reset settings = 0000_0000
Bit Name
7:0 HYB1[7:0] Programmable Hybrid Register 1.
Function
These bits are programmed with a coefficient value to adjust the hybrid response to reduce
near-end echo. This register represents the first tap in the 8-tap filter. When this register is set
to all 0s, this filter stage does not effect on the hybrid response. See "5.13.Transhybrid Bal-
ance" on page 29 for more information on selecting coefficients for the programmable hybrid.
Register 46. Programmable Hybrid Register 2
Bit
D7
D6
D5
D4
D3
HYB2[7:0]
R/W
D2
D1
D0
Name
Type
Reset settings = 0000_0000
Bit Name
7:0 HYB2[7:0] Programmable Hybrid Register 2.
Function
These bits are programmed with a coefficient value to adjust the hybrid response to reduce
near-end echo. This register represents the second tap in the 8-tap filter. When this register is
set to all 0s, this filter stage does not effect on the hybrid response. See "5.13.Transhybrid
Balance" on page 29 for more information on selecting coefficients for the programmable
hybrid.
78
Rev. 1.05