Si1000/1/2/3/4/5  
23.1.1. Operating Mode Control  
There are four primary states in the EZRadioPRO transceiver radio state machine: SHUTDOWN, IDLE,  
TX, and RX (see Figure 23.1). The SHUTDOWN state completely shuts down the radio to minimize current  
consumption. There are five different configurations/options for the IDLE state which can be selected to  
optimize the chip to the applications needs. "Register 07h. Operating Mode and Function Control 1" con-  
trols which operating mode/state is selected with the exception of SHUTDOWN which is controlled by SDN  
pin 20. The TX and RX state may be reached automatically from any of the IDLE states by setting the  
txon/rxon bits in "Register 07h. Operating Mode and Function Control 1". Table 23.2 shows each of the  
operating modes with the time required to reach either RX or TX mode as well as the current consumption  
of each mode.  
The transceivers include a low-power digital regulated supply (LPLDO) which is internally connected in  
parallel to the output of the main digital regulator (and is available externally at the VR_DIG pin). This com-  
mon digital supply voltage is connected to all digital circuit blocks including the digital modem, crystal oscil-  
lator, SPI, and register space. The LPLDO has extremely low quiescent current consumption but limited  
current supply capability; it is used only in the IDLE-STANDBY and IDLE-SLEEP modes. The main digital  
regulator is automatically enabled in all other modes.  
SHUTDOWN  
IDLE*  
TX  
RX  
*Five Different Options for IDLE  
Figure 23.1. State Machine Diagram  
Table 23.2. EZRadioPRO Operating Modes Response Time  
State/Mode  
Response Time to  
Current in State /Mode  
[µA]  
TX  
RX  
Shut Down State  
16.8 ms  
16.8 ms  
15 nA  
Idle States:  
Standby Mode  
Sleep Mode  
Sensor Mode  
Ready Mode  
Tune Mode  
800 µs  
800 µs  
800 µs  
200 µs  
200 µs  
800 µs  
800 µs  
800 µs  
200 µs  
200 µs  
450 nA  
1 µA  
1 µA  
800 µA  
8.5 mA  
TX State  
RX State  
NA  
200 µs  
NA  
30 mA @ +13 dBm  
18.5 mA  
200 µs  
Rev. 1.0  