C8051F50x-F51x
18.6.1.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 101 or 111
Nonmuxed 8-bit WRITE without Bank Select
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
EMIF ADDRESS (8 LSBs) from R0 or R1
EMIF WRITE DATA
T
T
WDS
WDH
T
T
T
ACS
ACW
ACH
/WR
/RD
Nonmuxed 8-bit READ without Bank Select
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
EMIF ADDRESS (8 LSBs) from R0 or R1
EMIF READ DATA
T
T
RDS
RDH
T
T
T
ACS
ACW
ACH
/RD
/WR
Figure 18.5. Non-multiplexed 8-bit MOVX without Bank Select Timing
Rev. 1.1
159