BATTERY PROTECTION IC FOR 1-CELL PACK
S-8241 Series
Rev.7.6_00
(10) Test Condition 10, Test Circuit 1 (Product with 0 V battery charging function)
(0 V battery charge start charger voltage)
Set V1 = V2 = 0 V and decrease V2 gradually. The voltage between VDD and VM at which VCO goes “H” (VVM + 0.1 V
or higher) is the 0 V battery charge start charger voltage (V0CHA).
(11) Test Condition 11, Test Circuit 1 (Product with 0 V battery charge inhibiting function)
(0 V battery charge inhibiting battery voltage)
Set V1 = 0 V and V2 = -4 V. Increase V1 gradually. The voltage between VDD and VSS at which VCO goes “H” (VVM
0.1 V or higher) is the 0 V battery charge inhibiting battery voltage (V0INH).
+
IDD
A
VDD
S-8241 Series
V1
VM
CO
VSS
I
A
DO
VM
V2
I
IDO
V4
A
A
CO
V
VCO
V
V
DO
V3
COM
Test circuit 1
Figure 5
Seiko Instruments Inc.
17