LC78622NE  
11. Bilingual Function  
MSB  
LSB  
0
Command  
RES = low  
0
0
0
0
0
0
1
1
1
0
0
0
1
1
1
0
0
0
0
0
1
STO CONT  
Lch CONT  
Rch CONT  
1
0
• Following a reset or when a stereo (28H) command has been issued, the left and right channel data is output to the  
left and right channels respectively.  
• When an Lch set (29H) command is issued, the left and right channels both output the left channel data.  
• When an Rch set (2AH) command is issued, the left and right channels both output the right channel data.  
12. De-Emphasis; Pin 29: EMPH/CONT6  
The preemphasis on/off bit in the subcode Q control information is output from the EMPH pin. When this pin is  
high, the LC78622NE internal de-emphasis circuit operates and the digital filters and the D/A converter output de-  
emphasized data.  
13. Digital Attenuator  
Digital attenuation can be applied to the audio data by setting the RWC pin high and inputting the corresponding  
two-byte command to the COIN pin in synchronization with the CQCK clock.  
MSB  
LSB  
1
Command  
RES = low  
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
0
0
1
1
ATT DATA SET  
DATA 00H set  
(MUTE –dB)  
0
ATT 4 STEP UP  
1
ATT 4 STEP DOWN  
ATT 8 STEP UP  
0
1
ATT 8 STEP DOWN  
ATT 16 STEP UP  
ATT 16 STEP DOWN  
0
1
• Attenuation setup  
Since the attenuation level is set to the muted state (a muting of –is specified by an attenuation coefficient of  
00H) after the attenuation level is reset, the attenuation coefficient must be directly set to EEH (using the ATT  
DATA SET command) to output audio signals. Note that the attenuation level can be set to one of 239 values from  
00H to EEH.  
These two-byte commands differ from the two-byte commands used for track counting in that it is only necessary  
to set RWC once and a two-byte command reset is not required. After inputting the target attenuation level as a  
value in the range 00H to EEH, sending an attenuator step up/down command will cause the attenuation level to  
approach the target value in steps of 4, 8, or 16 units as specified in synchronization with rising edges on the LRSY  
input. However, the ATT DATA SET command sets the target value directly. If a new data value is input during  
the transition, the value begins to approach the new target value at that point. Note that the UP/DOWN distinction  
is significant here.  