 浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第14页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第15页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第16页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第17页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第19页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第20页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第21页浏览型号K9F1216U0A-DIB00的Datasheet PDF文件第22页  
K9F1208Q0A K9F1216Q0A  
K9F1208D0A K9F1216D0A  
K9F1208U0A K9F1216U0A  
FLASH MEMORY  
NAND Flash Technical Notes (Continued)  
Error in write or read operation  
Within its life time, the additional invalid blocks may develop with NAND Flash memory. Refer to the qualification report for the actual  
data.The following possible failure modes should be considered to implement a highly reliable system. In the case of status read fail-  
ure after erase or program, block replacement should be done. Because program status fail during a page program does not affect  
the data of the other pages in the same block, block replacement can be executed with a page-sized buffer by finding an erased  
empty block and reprogramming the current target data and copying the rest of the replaced block. To improve the efficiency of mem-  
ory space, it is recommended that the read or verification failure due to single bit error be reclaimed by ECC without any block  
replacement. The said additional block failure rate does not include those reclaimed blocks.  
Failure Mode  
Detection and Countermeasure sequence  
Erase Failure  
Status Read after Erase --> Block Replacement  
Status Read after Program --> Block Replacement  
Read back ( Verify after Program) --> Block Replacement  
or ECC Correction  
Write  
Read  
Program Failure  
Single Bit Failure  
Verify ECC -> ECC Correction  
: Error Correcting Code --> Hamming Code etc.  
Example) 1bit correction & 2bit detection  
ECC  
Program Flow Chart  
If ECC is used, this verification  
operation is not needed.  
Start  
Write 80h  
Write 00h  
Write Address  
Wait for tR Time  
Write Address  
Write Data  
Write 10h  
*
No  
Program Error  
Verify Data  
Read Status Register  
Yes  
Program Completed  
No  
I/O 6 = 1 ?  
or R/B = 1 ?  
: If program operation results in an error, map out  
the block including the page in error and copy the  
target data to another block.  
*
Yes  
*
No  
Program Error  
I/O 0 = 0 ?  
Yes  
17  