Bulletin 1489-A
Circuit Breaker
Product Overview/Description
Bulletin 1489-A Circuit Breakers
ꢀ Energy-limiting design — protects downstream components better than
Table of Contents
Description ................... this page
Product Selection...... 7-21
Specifications.............. 7-25
Approximate
Dimensions................... 7-26
0
1
2
3
4
5
6
7
8
9
10
conventional breakers during short circuits
ꢀ Field-mountable options for selective applications
ꢀ IP2x Finger-Protection (Front)
ꢀ North America certifications: UL 489, CSA C22.2 No. 5
ꢀ International standards: CE Marked, and IEC (VDE) standards for
worldwide acceptance
ꢀ Ratings: UL/CSA — max. 480Y/277V AC – up to 14 kA interrupt rating;
IEC — max. 240/415V AC – 15 000 A interrupt rating
ꢀ 48V DC rating, 96V DC — 2-pole series
ꢀ A positively trip-free mechanism (breaker operation cannot be defeated
by holding the handle in the ON position)
ꢀ Trip curves: C and D
ꢀ Time delay (D Characteristic) for high inrush currents during inductive
start-ups such as motors, transformers and power supplies
ꢀ Superior shock and vibration resistance capabilities — helps to prevent
nuisance tripping
ꢀ Mounts on DIN Rail
ꢀ Wire connect, line and load (reversible)
ꢀ Optional terminals for ring lug terminals
Miniature Circuit Breaker for IEC Applications:
Industrial Circuit Breakers for North American Applications
ꢀ Energy limiting design - protects downstream components better
than conventional breakers during short circuits
415V AC 0.5...40 A
Standards Compliance
ꢀ Field mountable options for selective applications
ꢀ IP2x Finger-Protection (Front)
ꢀ North America certifications: UL 489, CSA 22.2 No. 5
UL 489
CSA C22.2 No. 5
EN/IEC 60947-2
ꢀ International standards: CE Marked, and IEC (VDE) standards for
Certifications
worldwide acceptance
UL Listed
ꢀ Ratings: UL/CSA — max. 480Y/277V AC – up to 14 kA interrupt
rating;
IEC — max. 240/415V AC – 15 000 A interrupt rating
ꢀ 48V DC rating, 96V DC — 2-pole series
CSA Certified
CE Marked
VDE Certified
Features
ꢀ A positively trip-free mechanism (breaker operation cannot be
defeated by holding the handle in the ON position)
ꢀ Designed manufactured and listed to UL 489 (CSA 22.2 No. 5)
ꢀ Thermal-magnetic protection
ꢀ Trip curves: C and D
ꢀ Time delay (D Characteristic) for high inrush currents during
inductive start-ups such as motors, transformers and power
supplies
ꢀ All ratings are HACR rated
ꢀ up to 14 kA Interrupting rating
ꢀ Finger–safe design (front)
ꢀ DIN Rail mounting
ꢀ Superior shock and vibration resistance capabilities — helps to
prevent nuisance tripping
ꢀ Mounts on DIN Rail
ꢀ Line and load wire connections
ꢀ Optional ring terminal connections (convertible)
ꢀ Wire connect, line and load (reversible)
ꢀ Optional terminals for ring lug terminals.
Description
The Bulletin 1489-A line includes:
ꢀ UL 489, CSA C22.2 No. 5
ꢀ 240V AC 0.5...40 A
Bulletin 1489-A Circuit Breakers for Branch Circuit protection are
available in 1-, 2-, and 3-pole construction and are rated 0.5...40 A
at 240V AC and 0.5...32 A at 480Y/277V AC for North American
applications (UL 489 and CSA C22.2 No. 5). The circuit breakers
also have a 1-pole 48V DC, 2-pole (series) 96V DC rating. For
EN\IEC applications the products are rated 415V AC, 48V AC
0.5...40 A.
ꢀ 480V/277V AC 0.5...32 A
ꢀ Miniature Circuit Breaker for EN/IEC Applications
EN/IEC 60947-2
415V AC 0.5...40 A
ꢀ SWD (0.5...20 A) Switching Duty for fluorescent lighting
applications
Thermal Magnetic Circuit Breakers
The Bulletin 1489-A Thermal Magnetic Circuit Breakers are general- 11
purpose devices suitable for the majority of industrial, inverse time
circuit breaker applications.
ꢀ HACR
ꢀ 1-pole 48V DC 0.5…40 A
ꢀ 2-pole (series) 96V DC 0.5…40 A
ꢀ 48V DC 0.5…40 A
They combine thermal and magnetic trip actions and provide
accurate overload and short-circuit protection for conductors and
12
connected equipment.
13
www.ab.com/catalogs
Preferred availability cat. nos. are bold.