RF R
ECEIVER
D
ECODER
H
YBRID
.
Technical Specification of HiR6 AM Modules
Ambient temperature = 25 Celsius.
o
HIRK-315
HIRK-433
HIR6-433
Electrical Specification
Supply Voltage
Supply Current.
Normal mode
Sleep
Receiver Frequency
Receiver Frequency
Working Frequency
(custom Frequencies Available)
Min
4.5
Typical
5.0
1.6
1
315.0
433.92
Max
5.5
Dimension
V
mA
uA
MHz
MHz
MHz
Note
200
450
stock frequency
stock frequency
Please contact
Sales Dept
I out = 8.5mA
I out = 8.5mA
Data output voltage: (any data output)
Logic Low
Logic High
Data output current: (any data output)
Logic Low
Logic High
Turn on Time
0.6
Vdd - .7
-25
10
V
V
-3dB Bandwidth
R.F Sensitivity (100% AM)
EMC Compliance
mA
mA
150
ms
+/- 2
+/- 3
MHz
-95
dBm
Complies to ETS300-339
DS010-6 May 06
©2006
REG No 277 4001, England.
Page 9