RF R
ECEIVER
D
ECODER
H
YBRID
.
Absolute Maximum Ratings
Supply Voltage (+5Vcc to GND)..........................................-0.3 to + 6 Volts.
o
Storage Temperature..........................................................-30 to +85 Celsius.
o
Operating Temperature....................................................... 0 to +70 Celsius.
HIRK-315
HIRK-433
HIR6-433
Technical Specification of HiRK AM Modules
Ambient temperature = 25 Celsius.
o
Electrical Specification
Supply Voltage
Supply Current
Receiver Frequency
Receiver Frequency
Working Frequency
(custom Frequencies Available)
Min
4.5
Typical
5.0
6
315.0
433.92
Max
5.5
200
450
Dimension
V
mA
MHz
MHz
MHz
Note
stock frequency
stock frequency
Please contact
Sales Dept
I out = 8.5mA
I out = 8.5mA
Data output voltage: (any data output)
Logic Low
Logic High
Data output current: (any data output)
Logic Low
Logic High
Turn on Time
0.6
Vdd - .7
-25
10
V
V
-3dB Bandwidth
R.F Sensitivity (100% AM)
Level of Emitted Spectrum
EMC Compliance
mA
mA
20
ms
+/- 400
KHz
-106
dBm
-70
dBm
Complies to ETS300-339
Technical Specification of HiRK FM Modules
Technical Specifications
Electrical Characteristics
Supply Voltage (Vcc)
Supply Current (Operating)
Receiver Frequency
R.F Sensitivity (100% AM)
433MHZ version
3dB Bandwidth
Data Rate
Turn on Time
Turn on Time
Level of Emitted Spectrum
Low Level Output Voltage
High Level Output Voltage
Operating Temperature Range
Min
4.5
Typical
5
5.7
433.92
-103
+/-150
300
8
-70
0.8
Vcc-1
-25
+80
9,600
5
Max
5.5
6.8
Dimension
V
mA
MHz
dBm
KHz
Hz
mSecs
mSecs
dBm
V
V
o
C
Notes
1
2
I = 200uA
I = 200uA
DS010-6 May 06
©2006
REG No 277 4001, England.
Page 8