欢迎访问ic37.com |
会员登录 免费注册
发布采购

R5F2134CWJFP 参数 Datasheet PDF下载

R5F2134CWJFP图片预览
型号: R5F2134CWJFP
PDF下载: 下载PDF文件 查看货源
内容描述: 瑞萨MCU [RENESAS MCU]
分类和应用:
文件页数/大小: 70 页 / 596 K
品牌: RENESAS [ RENESAS TECHNOLOGY CORP ]
 浏览型号R5F2134CWJFP的Datasheet PDF文件第46页浏览型号R5F2134CWJFP的Datasheet PDF文件第47页浏览型号R5F2134CWJFP的Datasheet PDF文件第48页浏览型号R5F2134CWJFP的Datasheet PDF文件第49页浏览型号R5F2134CWJFP的Datasheet PDF文件第51页浏览型号R5F2134CWJFP的Datasheet PDF文件第52页浏览型号R5F2134CWJFP的Datasheet PDF文件第53页浏览型号R5F2134CWJFP的Datasheet PDF文件第54页  
Preliminary document  
Specifications in this document are tentative and subject to change.  
Under development  
R8C/34W Group, R8C/34X Group, R8C/34Y Group, R8C/34Z Group  
5. Electrical Characteristics  
Table 5.7  
Voltage Detection 0 Circuit Electrical Characteristics  
Standard  
Symbol  
Parameter  
Condition  
Unit  
Min.  
2.70  
Typ.  
2.85  
6
Max.  
3.00  
150  
Vdet0  
Voltage detection level  
Voltage detection 0 circuit response time  
At the falling of VCC  
V
(3)  
At the falling of Vcc from  
µs  
5 V to (Vdet0 0.1) V  
Voltage detection circuit self power consumption  
VCA25 = 1, VCC = 5.0 V  
1.5  
µA  
µs  
td(E-A)  
Wait time until voltage detection circuit operation starts  
100  
(2)  
Notes:  
1. The measurement condition is VCC = 2.7 V to 5.5 V and Topr = 40 to 85°C (J version) / 40 to 125°C (K version).  
2. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA25 bit in the VCA2  
register to 0.  
3. Time until the voltage monitor 0 reset is generated after the voltage passes Vdet0.  
Table 5.8  
Voltage Detection 1 Circuit Electrical Characteristics  
Standard  
Typ.  
3.25  
3.40  
3.55  
3.70  
3.85  
4.00  
4.15  
4.30  
0.1  
Symbol  
Parameter  
Condition  
Unit  
Min.  
3.05  
3.20  
3.35  
3.50  
3.65  
3.80  
3.95  
4.10  
Max.  
3.45  
3.60  
3.75  
3.90  
4.05  
4.20  
4.35  
4.50  
(2)  
Vdet1  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
At the falling of VCC  
V
V
V
V
V
V
V
V
V
Voltage detection level Vdet1_7  
Voltage detection level Vdet1_8  
Voltage detection level Vdet1_9  
Voltage detection level Vdet1_A  
Voltage detection level Vdet1_B  
Voltage detection level Vdet1_C  
Voltage detection level Vdet1_D  
Voltage detection level Vdet1_E  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
Hysteresis width at the rising of Vcc in voltage detection  
1 circuit  
(3)  
At the falling of Vcc from  
60  
150  
µs  
Voltage detection 1 circuit response time  
5 V to (Vdet1_7 0.1) V  
Voltage detection circuit self power consumption  
VCA26 = 1, VCC = 5.0 V  
1.7  
µA  
µs  
td(E-A)  
100  
Wait time until voltage detection circuit operation starts  
(4)  
Notes:  
1. The measurement condition is VCC = 2.7 V to 5.5 V and Topr = 40 to 85°C (J version) / 40 to 125°C (K version).  
2. Select the voltage detection level with bits VD1S0 to VD1S3 in the VD1LS register.  
3. Time until the voltage monitor 1 interrupt request is generated after the voltage passes Vdet1.  
4. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA26 bit in the VCA2  
register to 0.  
Table 5.9  
Voltage Detection 2 Circuit Electrical Characteristics  
Standard  
Typ.  
Symbol  
Parameter  
Voltage detection level Vdet2  
Condition  
Unit  
Min.  
3.80  
Max.  
4.20  
Vdet2  
At the falling of VCC  
4.00  
V
V
Hysteresis width at the rising of Vcc in voltage detection  
2 circuit  
0.1  
(2)  
At the falling of Vcc from  
20  
150  
µs  
Voltage detection 2 circuit response time  
5 V to (Vdet2 0.1) V  
Voltage detection circuit self power consumption  
VCA26 = 1, VCC = 5.0 V  
1.7  
µA  
µs  
td(E-A)  
100  
Wait time until voltage detection circuit operation starts  
(3)  
Notes:  
1. The measurement condition is VCC = 2.7 V to 5.5 V and Topr = 40 to 85°C (J version) / 40 to 125°C (K version).  
2. Time until the voltage monitor 2 interrupt request is generated after the voltage passes Vdet2.  
3. Necessary time until the voltage detection circuit operates after setting to 1 again after setting the VCA27 bit in the VCA2  
register to 0.  
REJ03B0312-0010 Rev.0.10  
Apr 09, 2010  
Page 50 of 67  
 复制成功!