4283 Group
TEAB (Transfer data to register E from Accumulator and register B)
Instrunction D8
D0
Number of Number of Flag CY
Skip condition
–
words
cycles
code
0
0
0
0
1
1
0
1
0
0
1
A
16
16
16
16
2
1
1
–
Operation:
(ER7–ER4) ← (B)
(ER3–ER0) ← (A)
Grouping:
Register to register transfer
Description: Transfers the contents of register A and
register B to register E.
TLOA (Transfer data to register LO from Accumulator)
Instrunction D8
Flag CY
–
Skip condition
–
D0
Number of Number of
words
cycles
code
0
0
1
0
1
1
0
0
0
0
5
8
2
1
1
Operation:
(LO1, LO0) ← (A1, A0)
Grouping:
Other operation
Description: Transfers the contents of register A to logic
operation selection register LO.
TPU0A (Transfer data to register PU0 from Accumulator)
Instrunction D8
D0
Number of Number of Flag CY
words
Skip condition
–
cycles
code
0
1
0
0
0
1
1
1
1
0
8
F
2
1
1
–
Operation:
(PU03–PU00) ← (A3–A0)
Grouping:
Other operation
Description: Transfers the contents of register A to pull-
up control register PU0.
TPU1A (Transfer data to register PU1 from Accumulator)
Instrunction D8
Flag CY
–
Skip condition
–
D0
Number of Number of
words
cycles
code
0
1
0
0
0
1
1
1
0
0
8
E
2
1
1
Operation:
(PU13–PU10) ← (A3–A0)
Grouping:
Other operation
Description: Transfers the contents of register A to pull-
up control register PU1.
Rev.1.01 Mar 20, 2006 page 43 of 62
REJ03B0109-0101