MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
10
F/F0–15 Protect Register (FF015P)
<Address: H’0080 0224>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
FP15
0
FP14
0
FP13
0
FP12
0
FP11
0
FP10
0
FP9
0
FP8
0
FP7
0
FP6
0
FP5
0
FP4
0
FP3
0
FP2
0
FP1
0
FP0
0
<After reset: H’0000>
b
Bit Name
Function
R
R
W
W
0
FP15 (F/F15 protect bit)
FP14 (F/F14 protect bit)
FP13 (F/F13 protect bit)
FP12 (F/F12 protect bit)
FP11 (F/F11 protect bit)
FP10 (F/F10 protect bit)
FP9 (F/F9 protect bit)
FP8 (F/F8 protect bit)
FP7 (F/F7 protect bit)
FP6 (F/F6 protect bit)
FP5 (F/F5 protect bit)
FP4 (F/F4 protect bit)
FP3 (F/F3 protect bit)
FP2 (F/F2 protect bit)
FP1 (F/F1 protect bit)
FP0 (F/F0 protect bit)
0: Enable write to F/F output bit
1: Disable write to F/F output bit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Note: • This register must always be accessed in halfwords.
F/F16–20 Protect Register (FF1620P)
<Address: H’0080 0229>
b8
0
9
0
10
0
11
FP20
0
12
FP19
0
13
FP18
0
14
FP17
0
b15
FP16
0
<After reset: H’00>
b
Bit Name
Function
R
0
W
0
8–10
11
No function assigned. Fix to "0".
FP20 (F/F20 protect bit)
FP19 (F/F19 protect bit)
FP18 (F/F18 protect bit)
FP17 (F/F17 protect bit)
FP16 (F/F16 protect bit)
0: Enable write to F/F output bit
1: Disable write to F/F output bit
R
W
12
13
14
15
32180 Group User’s Manual (Rev.1.0)
10-30