MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
10
F/F16–19 Source Select Register (FF1619S)
<Address: H’0080 0223>
b8
9
0
10
0
11
0
12
0
13
0
14
0
b15
FS16
FS19
FS18
FS17
0
0
<After reset: H’0000>
b
Bit Name
FS19
Function
R
R
W
W
8, 9
00: TIO8 output
F/F19 source select bit
01: TIO8 output
10: Output event bus 0
11: Output event bus 1
10, 11
12, 13
14, 15
FS18
00: TIO7 output
R
R
R
W
W
W
F/F18 source select bit
01: TIO7 output
10: Output event bus 0
11: Output event bus 1
FS17
00: TIO6 output
F/F17 source select bit
01: TIO6 output
10: Output event bus 0
11: Output event bus 1
FS16
00: TIO5 output
F/F16 source select bit
01: Output event bus 0
10: Output event bus 1
11: Output event bus 3
These registers select the signal source for each output F/F (flip-flop). This signal source can be chosen to be a
signal from the internal output bus or an underflow output from each timer.
32180 Group User’s Manual (Rev.1.0)
10-29