MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
10
F/F6–15 Source Select Register (FF615S)
<Address: H’0080 0220>
b0
0
1
0
2
0
3
4
5
6
7
8
0
9
0
10
0
11
0
12
0
13
0
14
b15
FS15
0
FS14
0
FS13
0
FS12
0
FS11
0
FS10
FS9
FS8
FS7
0
FS6
0
<After reset: H’0000>
b
Bit Name
Function
R
0
W
0
0–2
3
No function assigned. Fix to "0".
FS15
0: TIO4 output
R
W
F/F15 source select bit
1: Output event bus 0
4
FS14
0: TIO3 output
R
R
R
R
R
W
W
W
W
W
F/F14 source select bit
1: Output event bus 0
5
FS13
0: TIO2 output
F/F13 source select bit
1: Output event bus 3
6
FS12
0: TIO1 output
F/F12 source select bit
1: Output event bus 2
7
FS11
0: TIO0 output
F/F11 source select bit
1: Output event bus 1
8, 9
FS10
00: TOP10 output
01: TOP10 output
F/F10 source select bit
10: Output event bus 0
11: Output event bus 1
10, 11
FS9
00: TOP9 output
R
R
W
W
F/F9 source select bit
01: TOP9 output
10: Output event bus 0
11: Output event bus 1
12, 13
FS8
00: TOP8 output
F/F8 source select bit
01: Output event bus 0
10: Output event bus 1
11: Output event bus 2
14
15
FS7
0: TOP7 output
R
R
W
W
F/F7 source select bit
1: Output event bus 0
FS6
0: TOP6 output
F/F6 source select bit
1: Output event bus 1
Note: • This register must always be accessed in halfwords.
32180 Group User’s Manual (Rev.1.0)
10-28