 浏览型号HD6417750SBP200的Datasheet PDF文件第748页浏览型号HD6417750SBP200的Datasheet PDF文件第749页浏览型号HD6417750SBP200的Datasheet PDF文件第750页浏览型号HD6417750SBP200的Datasheet PDF文件第751页浏览型号HD6417750SBP200的Datasheet PDF文件第753页浏览型号HD6417750SBP200的Datasheet PDF文件第754页浏览型号HD6417750SBP200的Datasheet PDF文件第755页浏览型号HD6417750SBP200的Datasheet PDF文件第756页  
From equation (1), if F = 0 and D = 0.5, the receive margin is 46.875%, as given by equation (2).  
When D = 0.5 and F = 0:  
M = (0.5 – 1 / (2 × 16) ) × 100% = 46.875% ............................................... (2)  
This is a theoretical value. A reasonable margin to allow in system designs is 20% to 30%.  
SCK2/05(6(7: As the manual reset pin is multiplexed with the SCK2 pin, a manual reset must  
not be executed while the SCIF is operating in external clock mode.  
When Using the DMAC: When using the DMAC for transmission/reception, inhibit output of  
RXI and TXI interrupt requests to the interrupt controller. If interrupt request output is enabled,  
interrupt requests to the interrupt controller will be cleared by the DMAC without regard to the  
interrupt handler.  
Serial Ports: Note that, when the SCIF pin value is read using a serial port, the value read will be  
the value two peripheral clock cycles earlier.  
Overrun Error Flag (SH7750): SCIF overrun error flag is not set in the case that overrun error  
and flaming error occurred simultaneously in receiving data, that means 17th byte data which  
overrun was accompanying with flaming error. In such case, only SCFSR2. ER flag which shows  
occurrence of flaming error is set. Receive FIFO stores data received before the overrun and does  
not store (i. e. lose) overrun data. SCIF has no bit which corresponds to SCFSR2. FER for the lost  
data.  
In addition to the overrun error handling software routine, exception handler should check co-  
occurrence of overrun error when a flaming error is occurred and when a co-occurrence is found,  
it should handle also overrun error (When (i) a overrun error solely occurred without  
accompanying with other receive error and (ii) when a parity error is accompanied with overrun  
error, usual overrun error handling can be used. Overrun error handling should rather be done  
primarily).  
Rev. 6.0, 07/02, page 700 of 986  